EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
REPUBLIC
>
14720
>
2900 - Site Mitigation Program
>
PR0542085
>
ARCHIVED REPORTS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 3:18:39 PM
Creation date
5/7/2020 3:08:28 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
RECORD_ID
PR0542085
PE
2965
FACILITY_ID
FA0010858
FACILITY_NAME
SJC PUBLIC WORKS /UTILITY-FLAG CITY
STREET_NUMBER
14720
STREET_NAME
REPUBLIC
STREET_TYPE
St
City
LODI
Zip
95242
APN
05532009
CURRENT_STATUS
02
SITE_LOCATION
14720 Republic St
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
321
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> i <br /> 4. The power distribution panel shall be completely assembled, wired, adjusted and <br /> tested at the factory. After assembly, the complete distribution switchboard will be <br /> tested for operation under simulated service conditions to assure the accuracy of the <br /> wiring and the functioning of all equipment. The distribution bus shall be given a <br /> dielectric test of 2200 volts for one minute between live parts and ground and between <br /> opposite polarities. The wiring and control circuits shall be given a dielectric test of <br /> 1500 volts for one minute between live parts and ground. A certified test report of <br /> all standard production test shall be available to the Engineer upon request. <br /> C. Short Circuit Rating <br /> 1. The complete bus assembly and breakers shall be rated to withstand mechanical forces <br /> I exerted during short circuit conditions when connected directly to a power source <br /> having available fault current of 22,000 amperes symmetrical at rated 480 volts. <br /> D. Bussing <br /> ' 1. All bus bars shall be tin plated copper. Bus sizing shall be based on NEMA standard <br /> temperature rise criteria of 65 degrees C over a 40 degrees C ambient (outside the <br /> enclosure). <br /> 2. A copper ground bus shall be furnished firmly secured to each vertical section <br /> structure and shall extend the entire length of the distribution switchgear. <br /> 3. All hardware used on conductors shall be high-tensile strength and zinc plated. All <br /> bus joints shall be provided with bellville washers. <br /> E. Distribution Breakers <br /> 1. The protective devices shall be molded case breakers with 22,000 amp minimum <br /> interrupting ratings and trip ratings as shown on the Contract one-line drawings. <br /> 2. Each breaker shall have a hasp for padlocking the breaker in the OFF position. <br /> iELECTRICAL <br /> 16000 - 37 <br />