EHD Program Facility Records by Street Name
>
R
>
REPUBLIC
>
14720
>
2900 - Site Mitigation Program
>
PR0542085
>
ARCHIVED REPORTS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 3:18:39 PM
Creation date
5/7/2020 3:08:28 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
RECORD_ID
PR0542085
PE
2965
FACILITY_ID
FA0010858
FACILITY_NAME
SJC PUBLIC WORKS /UTILITY-FLAG CITY
STREET_NUMBER
14720
STREET_NAME
REPUBLIC
STREET_TYPE
St
City
LODI
Zip
95242
APN
05532009
CURRENT_STATUS
02
SITE_LOCATION
14720 Republic St
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
321
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
t <br /> r <br /> e. Bypass switches shall be provided to allow bypassing any of the four above time <br /> delays during testing. <br /> I 10. Contacts shall be provided for starting the engine when the normal source fails. The <br /> contacts shall be double pole double throw (DPDT), and compatible with low voltage <br /> engine start signals. <br /> 11. A manual switch shall be provided to allow selection between commit/no-commit on <br /> transfer to emergency once the engine is signaled to start and the normal source restores <br /> ' before actual transfer. This switch shall be factory set in the no-commit position. <br /> 12. The controller shall commit-to-start engine which requires the engine to reach proper <br /> output and run at least the duration of the cooldown setting, regardless of whether the <br /> load is transferred. <br /> 13. Separate signal lights indicating when the switch is in the normal position, when the <br /> switch is in the emergency position shall be provided. Provide incandescent type lights <br /> with push-too-test feature, in oil-tight units with lenses. Nameplates shall be provided <br /> with each light to identify each light's function. Provisions shall be made to allow these <br /> lights to be mounted on the motor control center door. <br /> 14. Two auxiliary contacts shall be provided. One that closes when the switch is in the <br /> normal position and one that closes when the switch is in the emergency position. These <br /> auxiliary contacts shall be rated 1 amps at 120 volts. <br /> 1 15. Circuitry shall be provided to allow for connection of a remote contact to inhibit transfer <br /> to emergency source and/or retransfer to normal source, ignoring the associated timing <br /> relays. <br /> ' 16. A two position test switch shall be provided to simulate normal source failure. A <br /> nameplate shall be provided with the switch to identify its function. Provisions shall be <br /> made to allow this switch to be mounted on the motor control center compartment door. <br /> ' 17. All adjustments shall be fully field adjustable without the use of tools, meters, power <br /> supplies, or special test equipment. <br /> ' 18. Each adjustment resolution shall be settable within minimum increments of 1%. <br /> ' 19. Repetitive accuracy of timer, voltage and frequency settings over a temperature range <br /> of-20°C to 70°C shall be within+/-2%. <br /> ELECTRICAL <br /> 16000- 43 <br />