My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
REPUBLIC
>
14720
>
2900 - Site Mitigation Program
>
PR0542085
>
ARCHIVED REPORTS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 3:18:39 PM
Creation date
5/7/2020 3:08:28 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
RECORD_ID
PR0542085
PE
2965
FACILITY_ID
FA0010858
FACILITY_NAME
SJC PUBLIC WORKS /UTILITY-FLAG CITY
STREET_NUMBER
14720
STREET_NAME
REPUBLIC
STREET_TYPE
St
City
LODI
Zip
95242
APN
05532009
CURRENT_STATUS
02
SITE_LOCATION
14720 Republic St
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
321
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r1 SECTION 01667 <br /> 3 TESTING OF PIPELINES <br /> 4 <br /> 5 <br /> 1 6 PART 1: GENERAL <br /> 7 <br /> a 1.01 DESCRIPTION <br /> 9 <br /> 10 A. The work of this section consists of leak testing all pipelines and related valves and fittings. <br /> 11 Rejected work shall be retested, and if still rejected shall be repaired or replaced to the <br /> 12 satisfaction of the Engineer at the sole cost of the Contractor. <br /> 13 <br /> 14 B. Testing Methods: Gravity piping - low pressure water test; pressure lines, force mains, <br /> 15 sodium hypochlorite and bisulfite piping - high pressure water test; air and gas piping - air <br /> 16 pressure test. <br /> 17 <br /> 18 1.02 QUALITY ASSURANCE <br /> ' 20 A. Flow meters shall record the actual volume plus or minus 2 percent. <br /> 2191 <br /> zz B. Air and vacuum test gauges shall be ANSI 640.1, Grade 3A (plus or minus 0.25 percent of <br /> 23 full scale accuracy), dial range approximately twice the required test pressure. <br /> 24 <br /> 25 C. Water test gauges shall be ANSI B40.1, Grade 2A (plus or minus 0.5 percent of full scale <br /> ' 26 accuracy), dial range approximately twice the required test pressure. <br /> 27 <br /> 28 1.03 SUBMITTALS: In accordance with Section 01300. <br /> 2s <br /> 30 A. Accuracy certification by approved independent testing laboratories for flow meters and test <br /> 31 gauges. Certifications shall be dated no more than 90 days prior to actual system testing. <br /> 32 <br /> 33 B. Prior to testing, provide the following information: <br /> 34 <br /> 35 1. All Tests: Describe precautions that will be taken to protect System equipment that <br /> 36 might be damaged under test pressures, and the proposed method for rerouting sewer <br /> 37 flows where the system must remain in service. <br /> 38 <br /> 39 2. Air Test: Describe safety devices on air test equipment, and personnel safety <br /> 40 precautions during air tests. <br /> 41 <br /> 42 3. High or Low Pressure Water Test: Describe the proposed method for disposal of water <br /> 43 used in line testing. <br /> 44 <br /> 45 1.04 PROJECT CONDITIONS <br /> 46 <br /> 47 A. Testing shall not be performed until each system has been flushed or thoroughly cleaned <br /> 48 in accordance with procedures in the section that describes pipe line installation. <br /> 49 <br /> so <br /> TESTING OF PIPELINES <br /> ' 050594 01667-1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.