My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SITE INFORMATION AND CORRESPONDENCE
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
14749
>
2900 - Site Mitigation Program
>
PR0507155
>
SITE INFORMATION AND CORRESPONDENCE
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/8/2020 9:56:29 AM
Creation date
5/8/2020 9:44:41 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
SITE INFORMATION AND CORRESPONDENCE
RECORD_ID
PR0507155
PE
2950
FACILITY_ID
FA0007718
FACILITY_NAME
3 B'S TRUCK PLAZA
STREET_NUMBER
14749
Direction
N
STREET_NAME
THORNTON
STREET_TYPE
RD
City
LODI
Zip
95242
APN
05515026
CURRENT_STATUS
02
SITE_LOCATION
14749 N THORNTON RD
P_DISTRICT
004
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
344
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Three B's Truck Stop Page 2 of 2 <br /> 14749 N. Thornton Road August 17, 2011 <br /> Lodi, California <br /> contamination encountered at this site. To better ascertain if contaminant vapor is <br /> present and posing a threat to the public or employees in the building, the EHD requires <br /> you to relocate two of the soil vapor probes closer to the building. The probes should be <br /> set at 5 feet below ground surface (bsg), the depth cited by most authoritative guidance <br /> documents and used for vapor intrusion modeling. The shallower proposed depth (three <br /> feet bsg) may be used if supported by an authoritative guidance document appropriate <br /> for site conditions. <br /> At least one soil vapor probe should be installed in the driveway just west of the building <br /> to detect any contaminant vapor that has migrated toward the building. Another soil <br /> vapor probe should be installed to 5' bgs near the southern entry of the building to <br /> ascertain if any contaminant vapor is present between the historically contaminated <br /> dispenser islands to the south and the building. <br /> The EHD approves the location for proposed confirmation borings P-19, P-20, and P-21 <br /> for soil sample collection. The plan will be considered adequate and necessary with the <br /> above noted concerns properly addressed [H&S 25296.10(c)(3)]; if you concur you may <br /> proceed, otherwise submit a revised work plan with technical justification for an <br /> alternative investigation design that addresses the concerns noted above. Please <br /> submit a revised map showing the location of the soil vapor probes and a probe <br /> construction schematic. In addition, the Test is approved as necessary and adequate. <br /> The fee for an EHD permit for soil vapor probes (installation and removal the same day) <br /> is $500. If you plan to install soil vapor wells (probes that remain in beyond the day they <br /> were installed are considered a well), the application and inspection fee for an EHD <br /> permit is $375 plus $125 per each vapor well. Vapor probes to be left in place beyond <br /> the day they are installed (wells) must have a watertight surface seal, a locking cap for <br /> the casing, and a traffic box installed. The removal of these wells requires an EHD <br /> permit and fees equal to those of the installation. <br /> You may contact Michael Infurna, Senior REHS at (209) 468-3454 if you have any <br /> questions or wish to di s the site. <br /> Michael J. Infurna Jr., REHS Nuel C. Henderson Jr., PG <br /> Senior Registered Environmental Health Specialist Engineering Geologist <br /> cc: Mr. James L. Barton, CVRWQCB, Underground Storage Tank Unit, 11020 Sun Center <br /> Drive, #200, Rancho Cordova, CA 95670-6114 <br /> Mr. Kirk Larson, Underground Storage Tank Cleanup Fund, State Water Resources <br /> Control Board, P.O. Box 944212, Sacramento, CA 94244-2120 <br /> Mr. Tim Cuellar, AGE, 837 Shaw Rd., Stockton, CA 95215 <br /> 14749 Thornton Final SV & Conf-SB WP CML 5-17-11 <br />
The URL can be used to link to this page
Your browser does not support the video tag.