Laserfiche WebLink
File No. 20-3239-03 kn KLEINFELDER <br /> August 20, 1992 <br /> order to use standard leach lines, the County requires a percolation rate of 60 minutes per <br /> inch, or faster, at the Moot depth. In order to use sump pits, the County requires that <br /> a soil strata with a percolation rate of 30 minutes per inch, or faster, be located. The <br /> results of the percolation tests are presented in Table I, below. The County approved <br /> percolation test sheets are included with this report. <br /> TABLE I <br /> PERCOLATION TEST RESULTS <br /> Depth Percolation Rate <br /> Parcel No. Test No. feet min/in <br /> 12 MA 3 NP* <br /> P-1B 91/2 71/2 <br /> P-1C 14 20 <br /> 18 P-2A 3 NP* <br /> P-2B 91/2 6 <br /> P-2C 141/2 30 <br /> 13 P-3A 3 NP* <br /> P-3B 91/2 2 <br /> P-3C 141/2 31/2 <br /> 14 P-4A 3 NP* <br /> _ P4B 9 31/2 <br /> P4C 141/2 60 <br /> 5 P-5A 3 NP* <br /> P-5B 9 3 <br /> P-5C 131/2 1 <br /> 4 P-6A 3 15 <br /> P-6B 8 1 <br /> P-6C 14 NP* <br /> NP* - (No Percolation)- water level did not drop in last 30 minutes of test <br /> Copyright 1992 Kleinfelder, Inc. Page 3 of 5 <br />