My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2004 - 2007
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
85
>
2300 - Underground Storage Tank Program
>
PR0231656
>
COMPLIANCE INFO_2004 - 2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/26/2022 11:54:19 AM
Creation date
5/8/2020 4:22:14 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2004 - 2007
RECORD_ID
PR0231656
PE
2351
FACILITY_ID
FA0003635
FACILITY_NAME
ARCO 06080
STREET_NUMBER
85
Direction
E
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
LATHROP
Zip
95330
APN
19627010
CURRENT_STATUS
01
SITE_LOCATION
85 E LOUISE AVE
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
384
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AUG-20-3007 02 :07 PM GETTLER—RYAN INC. 925 551 4770 P. 03 <br /> D. Re,9ults of Testing/Servicing <br /> Software Version Installed: 325.02 <br /> Complete the follo Ing checklist: <br /> Yes No* is the audible alarm operational'! <br /> _ <br /> Yes ❑ No* Is the visual alarm operational? <br /> Yes No* Were all sensors visual) inspected,functionally tested,and confirmed operational? <br /> ❑ Yes ❑ No* Were all sensors installed at lowest point of secondary Containment and positioned so that other equipment will <br /> not interfere with their proper operation'! <br /> ❑ Yes ❑ No* If alarms wre relayed to a remote monitoring station. is all communications equipment (e.g. modem) <br /> E) N/A operational? <br /> Yeti 0 No* For pressurized piping systems, does the turbine automatically shut down if the pipingsecondary Containment <br /> ❑ N/A monitoring system detects a leak. fails to operate,or is electrically disconnected'? If yes: which sensors initiate <br /> positive shutdown? (Check(t!T that B Surnpfi'rench Sensors; ❑ Dispenser Containment Sensors. <br /> Did you confirm positive shut-down due to leaks and sensor failure/disconnection'! [EYes; ❑No. <br /> Yes ❑ No* For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no <br /> 0 N/A mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br /> fill int(s)and o eratin ro erl '! If so,tet who[ creent of tank capacity does the alarm tri8A r? .,--.% <br /> Ycs* S No Was any monitoring equipment replaced? If yes, identify specific sensors, probes,or other equipment replaced <br /> and list the manufacturer name and model for all replacement parts in Section E,below. _ <br /> © Yeti* Q No Was liquid found inside an secondury containments stems designed as d systems? (Check all that�r r atv <br /> q Y�' Y t3 rY�Y• app4v) <br /> Product; ❑Water. If yes,describe causes in SeCtion li.below. <br /> ❑ Yes ❑ No* Was monitoringsystemset-up reviewed to ensure proper settings'?Attach set up reports.if applicable <br /> Yes No* Is all monitoring ui mento crational per manufacturer'~..s)ecifications? <br /> * In Section E below,describe how and when these deficiencies were or will be corrected, <br /> E. Comments: <br /> CHECKED FUNCTIONALITY OF 91 FILL SUMP SENSOR WITH INSPECTOR TESTI:-:D OK <br /> (91 FILL SUMP ONLY) <br /> Pane 2 of.3 11.trot <br />
The URL can be used to link to this page
Your browser does not support the video tag.