My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
85
>
2300 - Underground Storage Tank Program
>
PR0231656
>
INSTALL_2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/26/2022 4:43:08 PM
Creation date
5/11/2020 2:26:27 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2011
RECORD_ID
PR0231656
PE
2351
FACILITY_ID
FA0003635
FACILITY_NAME
ARCO 06080
STREET_NUMBER
85
Direction
E
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
LATHROP
Zip
95330
APN
19627010
CURRENT_STATUS
01
SITE_LOCATION
85 E LOUISE AVE
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
422
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
VALIDATION CERTIFICATE / <br /> STRUCTURAL WARRANTY* <br /> CONTAINMENT Installation Checklist And Inspection Procedure <br /> SOLUTIONS For Fiberglass Underground Tank Installation <br /> *This checklist must be completed in Its entirety to validate the structural warranty.For warranty details,see the approriate <br /> Containment Solutions Tank Warranty Publication. <br /> Job Name Owner Date <br /> Job Site Ailidress City State <br /> Installation!Contractor Address Foreman <br /> Owner Representative Title <br /> Installation Checklist <br /> Please initial each Item as it Is completed. <br /> If not applicable,please mark N/A. C CL CL <br /> A.1 Pre Installation Testing-Single Wall Tanks c i U M w <br /> • Have you pressure tested the single-wall Unstable Excavations(all size tanks)require: <br /> 6',8,10'tanks to 5 psi? Minimum of 1/2 the tank diameter from ends <br /> 1 'tanks to 3 psi? and sides of tanks to excavation walls. <br /> • Ha you applied a soapy water solution Minimum 18"(24"preferred)between <br /> • er the entire tank surface? adjacent tanks(24"for 12'tanks). <br /> • er all fittings? <br /> • <br /> Have you carefully inspected for leaks as D.Anchoring <br /> iicated by bubbles? Have you reviewed the excavation for <br /> A.2.Pro Intallation Testing-Double Wall Tanks potential flooding from a high water table? <br /> Have you reviewed the excavation for <br /> • <br /> Have you tested double wall tanks in strict potential flooding from surface water runoff) <br /> conformance with the"Test Instructions" • Have you complied with the anchoring require <br /> Label No.L20002 which is on the tank? ments as stated in the Installation Instructions <br /> Caution:Do not connect the air pressure for <br /> line directly to any annular space fitting. Concrete anchor pad? <br /> • Complete the Hydrostatic lest of the secondary Concrete deadmen? <br /> containment collar. Is the owner's representative aware of the <br /> Did you fill the collar with water,let set anchoring requirements? <br /> r 12 hours,then check for leaks? Is anchoring not required for this installation? <br /> B.Bed and Backfill <br /> • Bed and backfill must meet all ASTM C-33 E.Installation Procedures <br /> requirements for quality and soundness. Have you provided the minimum 12"level <br /> • Approved Pea Gravel must consist of a clean bedding of approved backfill material? <br /> naturally rounded aggregate with a mix of particle Have you property pushed the initial 1 st two <br /> sizes not less than 1/8"or more than 3/4". 12"lifts of backfill under the tank bottoms, <br /> • Approved crushed stone or crushed gravel must between ribs and under the end caps to <br /> be washed with angular particle size not less than eliminate voids? <br /> 1/8"or more than 1/2". Have you completed the backfilling to the <br /> Does your bed and backrill meet these top of the tanks in uniform lifts? <br /> r6quirements? Did you completely fill the tank with water <br /> • Have you obtained a sieve analysis or product,after the backfilling had been <br /> from a qualified soil engineer or from property finished? <br /> • Elplier. <br /> backfill supplier? Exception:wet hole installation(see Con- <br /> e you attached the sieve analysis? tainment Solutions Publication"Installation <br /> Instructions For Fiberglass Reinforced <br /> Type: Plastic Underground Storage Tanks and <br /> • Whether you use gravel or crushed stone; Related Accessories". <br /> es no more than 5%of the backfill material • Did you comply with the requirements for <br /> ss through a#8 sieve? proper burial depth? <br /> C.Hole SI pad thickness for traffic loads? <br /> • Alb for proper spacing as required.Stable See Installation Instructions for specifics. <br /> Excavations(4'through 10'dia.tanks)require: • Containment Solutions requires the use of filter <br /> Minimum of 18"(24'preferred)between fabric for the following types of installations:Tidal <br /> adjacent tanks(24"for 12'tanks). conditions;areas subjected to frequently <br /> Chang-Minimum 18'(24"preferred)between tank ing ground water levels;Unstable soils(muck or <br /> s es and ends and the excavation walls landfills,see section A4 of Installation Instruc- <br /> ( "for 12'tanks). tions);Water conditions with silty soil. <br /> Did you use appropriate filter fabric as required <br /> (if applicable)? <br />
The URL can be used to link to this page
Your browser does not support the video tag.