My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
85
>
2300 - Underground Storage Tank Program
>
PR0231656
>
INSTALL_2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/26/2022 4:43:08 PM
Creation date
5/11/2020 2:26:27 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2011
RECORD_ID
PR0231656
PE
2351
FACILITY_ID
FA0003635
FACILITY_NAME
ARCO 06080
STREET_NUMBER
85
Direction
E
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
LATHROP
Zip
95330
APN
19627010
CURRENT_STATUS
01
SITE_LOCATION
85 E LOUISE AVE
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
422
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ONE CQMPA.NY. ONE WORLLI. ONE SOURCE. <br /> OPW 61T Drop Tube '' Ordering Specifications <br /> _.._..._.._.__..__..._......._......_.-._..._.___._. <br /> The OPW 61T Drop Tube is installed Drop Tube <br /> in the fill riser pipe to an underground Length <br /> storage tank. It is designed to transfer Product# in. mm lbs. kg ft. m <br /> product from the fill connection point 61T-7244 3 76 3.14 1.43 10 3.05 <br /> (between the delivery drop elbow and 61T-7268 4 102 6.18 2.80 12 3.66 <br /> tight-fill adaptor)to within 6"(or per local 617 '" 61T-7368 4 102 7.65 3.48 15 4,57 <br /> requirements)of the bottom of the tank. ----------- - - .................. 61T•7468 4 102 13 5.9 17 5.19 <br /> This allows for submerged filling of the Features Replacement gaskets for the 61T-4"and the 61 SO <br /> tank, resulting in a more efficient delivery Series are available.Order the OPW 61 TG(4000) <br /> flow rate while reducing the build-up of ® •052"Thick Drop Tube Walls— <br /> Deter denting and damage to the <br /> vapors or foam in the tank. tube upon installation or removal for <br /> long service life. <br /> OPW 61TC Coaxial Fill ♦Various Lengths and Diameters— <br /> Drop Tubes Accommodate a variety of tank <br /> The OPW 61TC Coaxial Drop Tube diameters and fill riser pipe sizes. <br /> is designed to replace an OPW 61T <br /> Conventional Drop Tube when Stage I <br /> Vapor Recovery is required and a vapor 1SC•21Spill <br /> Features Container <br /> recovery riser pipe is not available on <br /> the tank or would require excavation to ♦ .052"Thick Drop Tube Walls— <br /> the top of the tank. The 61TC is used Deter denting and damage to the tube <br /> in conjunction with OPW 633TC Coaxial upon installation or removal for long I i <br /> Vapor Recovery Adaptors to return <br /> service life. <br /> vapors to the tank truck through one ♦Various Lengths and Diameters— 633TC,or <br /> riser pipe during a fuel delivery to an Accommodate a variety of tank 633TCP <br /> underground storage tank.The upper diameters and fill riser pipe sizes. <br /> section of the 61TC is tapered to allow ♦ Fully Welded Retaining Brackets— <br /> vapors to return to the tank truck through Ensure a secure installation in the 61TC,or <br /> e i 61TCP <br /> the interstitial space between the riser riser pipe. <br /> pipe and outside wall of the drop tube. ♦Three Centering Springs—Enable <br /> Simultaneously, product is delivered to even flow of vapors back to the tank truck. - 4"Riser Pipe <br /> the tank through the center of the 61TC. <br /> OPW 61TCP Poppeted Ordering Specifications Underground <br /> Tank <br /> Coaxial Fill Drop Tubes Product# Diameter Length weight <br /> The OPW 61TCP Poppeted Coaxial in. mm ft. m Ibs. kg <br /> Fill Drop Tube is similar to the 61TC, <br /> but is spring-loaded.When used in 61TC•7270 4 102 13 3.05 8.64 3.93 <br /> conjunction with the OPW 633TCP, <br /> the 61TCP acts as a poppet to close 61TC•7272 4 102 16 4.88 13.82 6.28 <br /> off the vapor return side of the coaxial <br /> fill tube. <br /> O FO �� 617 Drop Tube Instruction Sheet Order Number:200652 <br /> 61TCP-3800 Instruction Sheet Order Number:H12064M <br /> A DOYER COMPANY <br /> North America Toll Free-TELEPHONE:(800)422-2525 <br /> Fax:(800)4213297•Email:domesticsales@opw-fc.co21 Important i %Works by OPW,Inc..VAPORSAVER,and all other OPW products must be used in compliance with all <br /> International-TELEPHONE:(513)870.3315 or(513)870.3261 I applicable federal,stale,provincial and local laws.rules and regulations.Product selection must be based on <br /> Fax:(513)870-3157•Email:intlsales@opw-facom•www.opw-fc.com i physical specifications and limitations,compatibility vdth the environment and material to be handled.All illustrations <br /> 9393 Princeton-Glendale Road•Hamilton.OH 45011 and specfications in this literature are based on the latest production information available at the time of publication. <br /> Prices,materials and specifications are subject to change at any time,and models may be discontinued at any time, <br /> in wider case,vviftut notice or obligation.OPW warrants solely to As customer titbl tine following products sold by <br /> r iJ 2009 OFW Fueling Components <br /> OPW will be free from defecls in materials and wo kmenship under normal use and conditions for Gle periods irdkcated, <br />
The URL can be used to link to this page
Your browser does not support the video tag.