Laserfiche WebLink
7400 Shoreline Drive /!A w 1441 I<apiolani Boulevard <br /> Suite 664, GeoTeoh� 1n!. Suite 1115 <br /> Stockton, California 95219 Geoengineering Consultants Honolulu, Hawaii 96814 <br /> Tel: 209-472-1822 Tel:808-468-9993 <br /> www.kanegeotech.com www.kanegeotech.com <br /> September 27, 2019 <br /> Anthony Lopes, SE, PE <br /> Siegfried Engineering <br /> 3428 Brookside Road <br /> Stockton, California 95219 <br /> Subject: Reclamation District 2074 Levee Monitoring Proposal <br /> Inclinometer Installation, Readings, and Reports <br /> San Joaquin County, California <br /> Dear Mr. Lopes: <br /> KANE GeoTech, Inc. (KANE GeoTech)is pleased to present this proposal to perform inclinometer <br /> casing installation, reading, and reports for Siegfried Engineering for a levee located in Stockton, <br /> California. This area in the Reclamation District 2074 has continuously show evidence of <br /> movement. Cracks in the pavement on top of the levee have been present for a number of years <br /> at this location. However, recently these cracks have deepened to approximately 3-ft. <br /> It is our understanding that due to the increase in depth, Siegfried Engineering believes that <br /> monitoring the movement in this area using inclinometers is now necessary. <br /> Scope of Work <br /> Toward this end, KANE GeoTech proposes the following Scope of Work: <br /> 1. Literature Review. KANE GeoTech will review available geotechnical information, reports,and <br /> maps provided by Siegfried Engineering and others which are pertinent to the Project. This <br /> includes, but is not limited to, soil (geotechnical) reports, surveys, past geological and <br /> engineering studies. It is understood that Siegfried Engineering will make available any <br /> applicable material in its possession. <br /> 2. Inclinometer Casing Installation. KANE GeoTech will obtain necessary permits from San <br /> Joaquin County to complete the subsurface drilling. KANE GeoTech will retain a California <br /> Licensed drillerto install inclinometer casing at two locations at the project site.The inclinometer <br /> casings will extend to a depth of 40-ft from the crest of the levee. Final locations will be <br /> determined in the field. KANE GeoTech personnel will log the subsurface conditions <br /> encountered during drilling. No samples will be taken or testing performed. <br /> 3. Manual Data Readings and Monitoring Reports. KANE GeoTech personnel will complete <br /> baseline readings for the two installed inclinometer casings as soon as possible following <br /> installation. KANE GeoTech will take four additional readings during the winter and spring to <br /> monitor the affect of the rain. <br />