Health and Safety Plan for <br /> Delineation and Destruction of Well B-1 <br /> 0 Sturdy work gloves, as needed. <br /> Respirators will be stored in clean containers when not in use. Respirator cartridges will be <br /> replaced in accordance with the following change-out schedule. <br /> Type of Cartridge Cartridge Change-out Schedule <br /> Particulate(i.e., HEPA) At least weekly or sooner if the employee detects an increase in breathing resistance. <br /> This will occur as the filter becomes loaded with particulate matter. <br /> Sorbent(i.e.,organic vapor) At the end of each week's use or sooner if the employee detects an abnormal odor or <br /> other indicator. <br /> Personnel who wear air-purifying respirators must be trained in their use and must have <br /> successfully passed a qualitative respirator fit test and medical evaluation within the last 12 <br /> months in accordance with and 29 CFR 1910.134. <br /> 4.2 Specific Action Levels <br /> If site monitoring data indicate that elevated concentrations do exist in the breathing zone, then <br /> corrective action will be taken to ensure the safety of the site workers. The breathing zone will be <br /> monitored using a photo-ionization detector (PID). In the table below, "sustained" refers to a <br /> consistent reading lasting 5 seconds or more. <br /> Activity Action Level Level of Respiratory Protection <br /> Drilling,sampling, managing Sustained PID reading of 2 to Sample the air using a 1,1-dichloroethene(1,1-DCE) <br /> samples and IDW 25 parts per million(ppm) Draeger®tube(or equivalent). If 1,1-DCE is not detected <br /> above background above 5 ppm,work may continue without additional <br /> respiratory protection. <br /> If 1,1-DCE is detected at or above 5 ppm, respirators <br /> shall be used to reduce exposure. <br /> Drilling,sampling, managing Sustained PID reading of 25 to Workers will don respirators to reduce exposures. <br /> samples and IDW 50 ppm above background Workers will use Draeger®tubes as available and record <br /> results but will maintain respirator use until PID readings <br /> are less than 25 ppm above background for at least 30 <br /> consecutive minutes,provided 1,1-DCE levels are below <br /> 5 ppm. <br /> Drilling,sampling, managing Sustained PID reading of 51 Stop work and evacuate to a safer breathing zone. PPE <br /> samples and IDW ppm or more above and potential exposures must be reevaluated. <br /> background <br /> 10275-4 <br /> D U D E K 18 June 2017 <br />