Laserfiche WebLink
S0 JOA U 1 Environmental Health Department <br /> u ; i y <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> HEWITT ALINEMENT SERVICE 925 S EL DORADO ST, STOCKTON November 05, 2018 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 601 CCR 66262.34(d)Stored hazardous waste onsite greater than 180 days. <br /> The following containers were observed without an empty date: <br /> In the main shop: <br /> -One blue 5 gallon plastic bucket containing used absorbent and metal fines(1/2 full) <br /> -One blue 15 gallon steel drum containing parts washer fluid (1/2 full) <br /> -One 1 pint bucket containing metal fines(1/4 full) <br /> In the used oil area: <br /> -One white 5 gallon plastic bucket coontaining used oil and used oil filters(1/2 full) <br /> -One blue 15 gallon metal drum containing unpunctured/uncrushed used oil filters(1/4 full) <br /> -One 5 gallon catch pan containing metal fines(1/4 full) <br /> Facilities who generate less than 1000 kg of hazardous waste per month and do not exceed 6000 kg of waste <br /> stored on site at any time may store waste on site up to 180 days. Immediately contact a licensed hazardous waste <br /> hauler to dispose of this waste under manifest and submit a copy of the manifest to the EHD. <br /> This is a repeat violation, Class ll. <br /> 605 CCR 66262.34(f) Failed to completely label containers or portable tanks of hazardous waste. <br /> In the main shop: <br /> -One blue 5 gallon plastic bucket containing used absorbent and metal fines(1/2 full)was observed with a faded <br /> hazardous waste label. <br /> -One blue 15 gallon steel drum containing parts washer fluid (1/2 full)was observed with a label missing the <br /> accumulation start date and the contents. <br /> -One 1 pint bucket containing metal fines(1/4 full)was observed without a hazardous waste label. <br /> In the used oil area: <br /> -One white 5 gallon plastic bucket containing used oil and used oil filters(1/2 full)was observed without a hazardous <br /> waste label. <br /> -One blue 15 gallon metal drum containing unpunctured/uncrushed used oil filters was observed without hazardous <br /> waste label. <br /> -One 5 gallon catch pan containing metal fines(1/4 full)was observed without a hazardous waste label. <br /> -One red 15 gallon metal drum containing used oil (full)was observed with a blocked hazardous waste label. <br /> All hazardous waste containers shall be marked with the following information: <br /> -the words"Hazardous Waste" <br /> -name and address of generator <br /> -hazardous properties <br /> -physical state <br /> -composition (contents) <br /> -accumulation start date <br /> Immediately label these containers and ensure that all hazardous waste containers are marked with all the required <br /> information. <br /> This is a repeat violation, Class II. <br /> Overall Inspection Comments: <br /> FA0009108 PR0513644 SCO01 11/05/2018 <br /> EHD 22-01 Rev.9/20/2019 Page 6 of 7 Small Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />