Laserfiche WebLink
Quarterly Monrtonng and Sampling Report(Q3 2001) 4 <br /> Ranch Market 23569 Santa Fe Road Riverbank California August 9 2001 <br /> dedicated well pump, pressure tank, concrete pad, and well-related underground electrical and <br /> water service line was installed Details of the well installation are described in SECOR's <br /> Domestic Well Installation Report (DW-2R), dated February 1, 2001 <br /> On January 8, 2001, SECOR sampled DW-2R and submitted the water sample to Kiff Analytical <br /> for BTEX, TPHg, oxygenates, 1,2-DCA, and EDB using EPA method 8260B The sample was <br /> also analyzed at CLS for Nitrate/Nitnte using EPA method 300 0 SECOR collected <br /> confirmation water samples from DW-2R on January 11, 2001, and again on January 15, 2001 <br /> Analytical data is summarized in Table 3 <br /> After review of the confirmation samples, the San Joaquin County Environmental Health <br /> Department (SJCEHD) requested the well be brought online On January 18, 2001, SECOR met <br /> with Mr Michael Infurna with SJCEHD for the final inspection of well DW-2R The water <br /> service from the Aero Pure Water supply tank was disconnected and the water valve was opened, <br /> allowing DW-2R to supply water to the home on the Pantoja Property <br /> Groundwater Monitoring <br /> I <br /> Water Table Elevations and Gradient <br /> On July 3, 2001, SECOR personnel measured the depth to water in each of the ten site-related <br /> • groundwater monitoring wells (Table 3) A water level indicator was used to gauge the wells to <br /> the nearest 0 01 foot A groundwater elevation contour map indicates that groundwater flow is <br /> generally toward the south at a gradient of 0 002 ft/ft (Figure 4) Current and historical <br /> groundwater monitoring data are summarized in Table 3 <br /> Separate-Phase Petroleum Thickness <br /> Well gauging and sampling efforts for third quarter 2001 did not detect separate-phase petroleum <br /> hydrocarbons (SP)in any of the wells monitored(Table 3) Historically, SP has not been present <br /> in the groundwater monitoring wells at the site <br /> Groundwater Samnlin R <br /> Well Purging <br /> Groundwater monitoring wells were purged using a submersible pump and disposable bailers <br /> until pH, temperature, and conductivity readings had stabilized Temperature, conductivity, and <br /> pH readings were recorded in the ten wells, at regular purge intervals of one casing volume, with <br /> a portable instrument that was calibrated before the wells were purged Water purged from the <br /> ten groundwater monitoring wells was stored in drums on site, pending characterization and <br /> disposal <br /> • <br /> File Ranch Market\ReportlRiverbank-01-3Q <br />