Final Remediation Plan Page 2
<br /> Ranch Market 23569 South Santa Fe Road Riverbank CA February 28 2001
<br /> • o Domestic Well Video Survey Report, May 23, 2000 (SECOR),
<br /> o Evaluation of Potable Water Sources, August 21, 2000 (SECOR),
<br /> o Soil and Groundwater Assessment Report, September 6, 2000(SECOR),
<br /> o Additional Evaluation of Potable Water Sources, September 14, 2000 (SECOR),
<br /> o Notification of Bottled Water Service, September 19, 2000(SECOR),
<br /> o Problem Assessment Report, November 8, 2000 (SECOR),
<br /> o DW-2 Well Destruction Work Plan, December 12, 2000 (SECOR),
<br /> o Addendum to The Problem Assessment Report, December 18, 2000(SECOR),
<br /> o Quarterly Montionng and Sampling Report(Q4/2000), December 19, 2000(SECOR),
<br /> o DW-2 Well Destruction Report, January 26, 2000 (SECOR),
<br /> o Domestic Well Installation Report(DW2R), February 1, 2001 (SECOR)
<br /> 2.3 Underground Storage Tank Removal
<br /> The site was previously operated as a convenience store and retail gasoline fueling facility
<br /> with three single walled steel gasoline underground storage tanks (USTs) as shown on Figure
<br /> 3 The date of installation, operation history, and inventory records of the USTs at the Site is
<br /> unknown The three USTs two 1,000-gallon and one 5,000-gallon UST and associated
<br /> pumps were removed from the Site on May 20, 1991 The single dispenser island was located
<br /> directly over the tank pit, so no dispenser or fuel line soil samples were collected During
<br /> removal of the USTs, soil contamination was observed at the bottom of the tank excavation
<br /> and documented in five soil samples collected after removal of the tanks (Figure 3, Table 1)
<br /> 2.4 Domestic Wells and Septic Fields
<br /> The Site and the following three residences use septic fields for treatment of waste water and
<br /> have domestic wells that are the sole source of water for each residence
<br /> Owner Address Parcel Number Well#
<br /> Ranch Market 23569 S Santa Fe Road APN 249-070-12 DW-1
<br /> Juan Pantoja 23565 S Santa Fe Road APN 249-070-11 DW-2R
<br /> Jose Cano 23659 S Santa Fe Road APN 249-070-10, DW-3
<br /> Troy Roe 23665 S Santa Fe Road APN 249-070-09, DW-4
<br /> The location of the domestic wells and septic field on each property is shown on Figure 2 and
<br /> the well completion information is summarized in Table 2 Well DW-1 is sampled monthly
<br /> and Wells DW-2R, DW-3, and DW-4 are sampled quarterly for the presence of benzene,
<br /> toluene, ethyl benzene, and xylenes (BTEX), total petroleum hydrocarbons quantified as
<br /> gasoline (TPHg), oxygenates, 1,2-Dichloroethane (1,2-DCA), and 1,2-Dibromoethane (EDB)
<br /> using Environmental Protection Agency (EPA) method 8260B
<br /> 2.4.1 Domestic Well DW-2 Shut Down and Destruction
<br /> On October 7, 1999, domestic well DW-2 was sampled and reported to contain MtBE at 38
<br /> parts-per-billion (ppb) (Table 3) Since additional water samples collected in November and
<br /> December 1999 contained MtBE, the RWQCB required well DW-2 to be removed from
<br /> service and the home supplied with an alternative potable water supply In January 2000,
<br /> DW-2 was shut down and a temporary water line was run from the Ranch Market well DW-1
<br /> File FRP report doe SECOR International Incorporated