My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SITE INFORMATION AND CORRESPONDENCE
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
SCHULTE
>
14700
>
2900 - Site Mitigation Program
>
PR0542399
>
SITE INFORMATION AND CORRESPONDENCE
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/18/2020 2:17:17 PM
Creation date
5/18/2020 2:15:39 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
SITE INFORMATION AND CORRESPONDENCE
RECORD_ID
PR0542399
PE
2960
FACILITY_ID
FA0024361
FACILITY_NAME
OWENS-BROCKWAY GLASS CONTAINER INC
STREET_NUMBER
14700
STREET_NAME
SCHULTE
STREET_TYPE
RD
City
TRACY
Zip
95377
APN
209240024
CURRENT_STATUS
01
SITE_LOCATION
14700 SCHULTE RD
P_LOCATION
03
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WASTE DISCHARGE REQUTAENTS NO. -6- <br /> OWENS-BROCKWAY <br /> OWENS-ILLINOIS GLASS FURNACE FACILITY <br /> SAN JOAQUIN COUNTY <br /> 7. The pond system shall have sufficient capacity to accommodate allowable wastewater <br /> flow, design seasonal precipitation, seasonal ancillary inflow, and infiltration during the <br /> wet season. Design seasonal precipitation shall be based on total annual precipitation <br /> using a return of 100 years, distributed monthly in accordance with historical rainfall <br /> patterns. <br /> 8. Pond freeboard shall never be less than two feet in any pond as measured vertically from <br /> the water surface to the upper surface of the lowest adjacent dike or levee. <br /> 9. On or about 15 October each year, available pond storage capacity shall at least equal the <br /> volume necessary to comply with Discharge Specifications No. 7 and 8. <br /> 10. Treated process wastewater discharged to the process wastewater ponds shall not exceed <br /> a specific conductivity value of 1,800 µmhos/cm. Compliance with this Discharge <br /> Specification shall be implemented within two years of the date of this Order. In the <br /> meantime, the Discharger shall use best management practices to reduce the amount of <br /> salts entering the wastewater, and to maintain compliance with all other Prohibitions and <br /> Specifications contained within this Order. <br /> C. Solids Disposal Requirements: <br /> 1. Collected screenings, sludge, and other solids removed from liquid wastes shall be <br /> disposed of in a manner approved by the Executive Officer, and consistent with <br /> Consolidated Regulations for Treatment, Storage, Processing, or Disposal of Solid <br /> Waste, as set forth in Title 27, CCR, Division 2, Subdivision 1, Section 20005, et seq. <br /> 2. Any proposed change in sludge use or disposal practice from a previously approved <br /> practice shall be reported to the Executive Officer and U.S. Environmental Protection <br /> Agency(EPA) Regional Administrator at least 90 days in advance of the change. <br /> 0 <br /> 3. Septic tank cleanings shall be performed only l y a duly authorized service. <br /> 4. If the State Water Resources Control Board and the Regional Water Resources Control <br /> Board are given the authority to implement regulations contained in 40 CFR 503, this <br /> Order may be reopened to incorporate appropriate time schedules and technical <br /> standards. The Discharger shall comply with the standards and time schedules contained <br /> in 40 CFR 503 whether or not they have been incorporated into this Order. <br /> D. Groundwater Limitations: <br /> 1. The discharge, in combination with other sources, shall not cause underlying <br /> groundwater to contain waste constituents in concentrations statistically greater than <br /> background water quality, except for coliform. For coliform, increases shall not cause <br /> the most probable number of total coliform organisms to exceed 2.2/100 ml over any 7- <br /> day period. <br />
The URL can be used to link to this page
Your browser does not support the video tag.