Laserfiche WebLink
March 27, 2020 Lab ID : STK2O32768 <br /> Frank C Alegre Trucking Inc. Customer : 3-13002 <br /> Quality Control-Inorganic <br /> Constituent Method Date/ID Type Units Cone. QC Data DQO Note <br /> Metals <br /> Thallium 6010B 03/05/20:20381 IAC CCB ppm 0.0033 0.02 <br /> Vanadium 6010B 03/05/20:203811AC CCV ppm 1.000 101% 90-110 <br /> CCB ppm -0.0012 0.01 <br /> CCV ppm 1.000 -0.08% 90-110 <br /> CCB m -0.0013 0.01 <br /> inc 6010B 03/05/20:20381 IAC CCV ppm 1.000 100% 90-110 <br /> CCB ppm -0.0049 0.02 <br /> CCV ppm 1.000 -0.5% 90-110 <br /> CCB ppm -0.0049 0.02 <br /> enic RCRA 03/26/20:201595ac ExBlk mg/L -0.0028 0.01 <br /> s 1 <br /> PDS m 4.000 1 186% 75-125 1 430 <br /> Definition <br /> PDS :PDS failed,matrix-Post Digestion Spike(PDS)not within Acceptance Range(AR)because of matrix interferences affecting this <br /> analyte.Data was accepted based on the LCS recovery. <br /> CCV :Continuing Calibration Verification-Analyzed to verify the instrument calibration is within criteria. <br /> CCB :Continuing Calibration Blank-Analyzed to verify the instrument baseline is within criteria. <br /> Blank :Method Blank-Prepared to verify that the preparation process is not contributing contamination to the samples. <br /> ExBlk :TCLP/STLC Extraction Blank-Prepared to verify that the preparation process is not contributing contamination to the samples. <br /> LCS :Laboratory Control Standard/Sample-Prepared to verify that the preparation process is not affecting analyte recovery. <br /> MS Matrix Spikes-A random sample is spiked with a known amount of analyte.The recoveries are an indication of how that sample <br /> matrix affects analyte recovery. <br /> MSD :Matrix Spike Duplicate of MS/MSD pair-A random sample duplicate is spiked with a known amount of analyte.The recoveries <br /> are an indication of how that sample matrix affects analyte recovery. <br /> MSRPD :MS/MSD Relative Percent Difference(RPD)-The MS relative percent difference is an indication of precision for the preparation <br /> and analysis. <br /> ND :Non-detect-Result was below the DQO listed for the analyte. <br /> <'/4 :High Sample Background-Spike concentration was less than one forth of the sample concentration. <br /> DQO :Data Quality Objective-This is the criteria against which the quality control data is compared. <br /> Explanation <br /> 220 :The CCB was greater than the DQO.However,all results were either five times greater than the CCB concentration or ND relative <br /> to the PQL. <br /> 430 :Post Digestion Spike(PDS)not within Acceptance Range(AR)because of matrix interferences affecting this analyte.Data was <br /> accepted based on the LCS recovery. <br /> 435 :Sample matrix may be affecting this analyte.Data was accepted based on the LCS or CCV recovery. <br /> Page 8 of 8 <br />