My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1469
>
2300 - Underground Storage Tank Program
>
PR0231126
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/30/2020 4:27:09 PM
Creation date
5/19/2020 2:59:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0231126
PE
2361
FACILITY_ID
FA0001570
FACILITY_NAME
UNITED # 5447
STREET_NUMBER
1469
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
08818030
CURRENT_STATUS
01
SITE_LOCATION
1469 E HAMMER LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
138
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CC) PEI/RM200 - 17 <br /> 6 . 2 . 2 Description of Test . The spill bucket is <br /> 6 . SPILL BUCKET AND filled with water. The water level is measured at the <br /> CONTAINMENT SUMP beginning and end of the test. <br /> TESTING 6 . 2 . 3 Test Equipment . Test equipment shall <br /> include : <br /> 6 . 1 General . Spill buckets and containment sumps for water; <br /> tank systems are neither intended nor designed for the measuring stick that is accurate to within 1 / 16 <br /> storage of petroleum products , but rather to contain small (0 .063 ) inch and of sufficient length ; <br /> leaks and spills for short periods of time . This section <br /> describes the procedures used to test the integrity of spill plumber ' s plug (appropriate size, if used) ; <br /> buckets and containment sumps to ensure that they do not stopwatch or other time-measurement device <br /> leak. capable of measuring a 1 - second increment . <br /> 6 . 2 Spill Bucket Integrity Testing — Hydrostatic 6 . 2 .4 Preparation . <br /> Test Method . <br /> 1 . Care should be taken when conducting the test <br /> WARNING• Do not use fuels such as Baso- in the rain or during freezing weather condi- <br /> line , E85 or diesel as a test fluid because tions . <br /> they present a serious fire and safety 2 . Remove and properly dispose of any liquid and <br /> hazard . Gasoline vapors are flammable debris (leaves , sediment and trash) in the spill <br /> and can explode if exposed to an ignition bucket . Clean the spill bucket and examine it for <br /> source such as a spark or open flame . If damage, defects or improperly installed compo- <br /> a tank or containment area is not tight , nents . If there are loose components (e. g . , loose <br /> using fuel as the test fluid will cause a band clamps or bolts) , tighten these items before <br /> release into the soil or groundwater. conducting the integrity test . If there are items <br /> that must be repaired or replaced (e . g . , deterio - <br /> rated gaskets/seals or drain valves) , notify the <br /> 6 . 2 . 1 Purpose . This method is used to test the owner/operator. <br /> integrity of single-walled spill buckets or the pri- <br /> mary containment of secondarily contained spill 3 . Examine the fill cap and adapter fitting for <br /> buckets . loose , missing or damaged parts , and make <br /> necessary repairs . Complete any repairs before <br /> putting water in the spill bucket. Make sure that <br /> the seal on the fill cap is present and in good <br /> condition . The cap must fit securely and be leak- <br /> water Level tight on the riser. The water level during the test <br /> typically will be above the cap , so a leaking cap <br /> will result in a failed test . As an alternative to <br /> a tight-fill cap , use a plumber ' s plug in the fill <br /> riser if approved by the authority having juris- <br /> diction (AHJ) and tank owner. <br /> 4. The spill bucket drain valve, if present, must <br /> be leak-tight to pass the test. If it is not leak- <br /> tight, it may be possible to simply remove and <br /> permanently plug the drain valve . However, if <br /> you choose to permanently plug , ensure that the <br /> local regulations allow this modification . <br /> FIGURE 6-1. The hydrostatic method of determining 5 . If the spill bucket is found to have cracks , loose <br /> spill bucket integrity uses water to detect leaks. The parts or separation of the bucket from the fill <br /> measuring stick must be placed in the same location pipe, it is not considered to be liquid-tight. This <br /> at the beginning and end of the test period to ensure visually indicates a test failure . <br /> accurate water level readings. <br /> peLorg <br />
The URL can be used to link to this page
Your browser does not support the video tag.