Laserfiche WebLink
A J OA U I Environmental Health Department <br /> COUNTY <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Pacific Service Station 16131 PACIFIC AVE, STOCKTON August 19, 2020 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 301 HSC 25292.1(a) UST system is not operated to prevent unauthorized release, including spills and overfills. <br /> OBSERVATION: The fuel filters under the dispensers are not located to allow drips and leaks to drain back into the <br /> UDCs. <br /> REGULATION GUIDANCE: The underground storage tank system shall be operated to prevent unauthorized <br /> releases. <br /> CORRECTIVE ACTION: Immediately provide approved secondary containment for the filters under permit and <br /> inspection by the EHD. <br /> This is a Class II violation. <br /> 319 CCR 2635, 2637.1, 2665, 2712 No spill bucket, failed to contain 5 gallons, no means to keep it empty, or failed to be <br /> tested. <br /> OBSERVATION: The diesel and 91 spill container failed to have a minimum capacity of five gallons. <br /> REGULATION GUIDANCE: All spill containers shall have a minimum capacity of five gallons. <br /> CORRECTIVE ACTION: Immediately contact a properly licensed, trained, and certified contractor to repair or <br /> replace the spill container under permit and inspection of the EHD. <br /> This is a minor violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by 09/18/2020 . <br /> To minimize person to person contact EHD is choosing to write the name of person receiving the report instead <br /> of having them sign. Starting September 1, 2018, all in-office CERS help will be provided at EHD hourly rate <br /> ($152). To schedule an appointment, please call (209) 468-3420. <br /> Documents provided during inspection: Return to compliance certification form, corrective action statement <br /> form and list of approve CUPA free traning classes. <br /> AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING <br /> THIS FACILITY BACK INTO COMPLIANCE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Received by: Date: August 19, 2020 Inspector: Inspector Phone: <br /> Printed Name and Title: PAUL NSO, EH Specialist (209)468-3432 <br /> Dave Singh, Cashier <br /> FA0002324 PR0231223 SCO01 08/19/2020 <br /> EHD 23-01 Rev.8/11/2020 Page 7 of 7 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />