Laserfiche WebLink
r <br /> a._ <br /> ` 433 Scotts, Stockton <br /> Page 2 <br /> northeast'of MW2 and further away from the former UST location should be <br /> evaluated. The soil boring proposed for the apartment;parking lot should be <br /> completed to a minimum depth of 35 feet since soil sample-MW2-35'.had_____�_._- <br /> contamination. The boring northwest of MW-1 on.the Sierra Lumber site may not , <br /> be necessary since an environmental assessment was.'conducted in June 2004 <br /> at the lumber yard and two borings were drilled in that location and soil and <br /> groundwater samples were collected. The information from that site work should <br /> be used to evaluate the extent of contamination in that'direction. An addendum <br /> to the February 15, 2005, work plan that addresses the above comments should <br /> be submitted to EHD by April 11, 2005. <br /> If you have any questions contact me at (209)468-3449. <br /> Donna Heran, REHS, Director <br /> I, Environmental Health Department <br /> Margaret Lagorio, Supervising REHS <br /> Unit IV <br /> c: CVRWQCB —Jim Barton <br /> AGE — Dan Kalmbach <br />