My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0010337
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
SHAW
>
1500
>
3500 - Local Oversight Program
>
PR0545688
>
ARCHIVED REPORTS_XR0010337
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/21/2020 3:39:54 PM
Creation date
5/21/2020 2:59:51 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0010337
RECORD_ID
PR0545688
PE
3528
FACILITY_ID
FA0003634
FACILITY_NAME
CANTEEN CORPORATION
STREET_NUMBER
1500
Direction
N
STREET_NAME
SHAW
STREET_TYPE
RD
City
STOCKTON
Zip
95205
APN
14326008
CURRENT_STATUS
02
SITE_LOCATION
1500 N SHAW RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
250
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3.0 AIR MONITORING <br /> 3 1 Air Monitoring <br /> Air monitoring must be performed on sites as required, in accordance with AES-RS Respiratory Protection Program <br /> Organic vapor concentrations are monitored in the field with a flame ionization detector (FID) or photo-ionization <br /> detector (PID) All readings are taken in the workers' breathing zone to determine whether an action level has been <br /> met and/or exceeded Air monitoring results must be documented <br /> Air monitoring action levels (Table 3-1) have been developed to indicate the chemical concentrations in the breathing <br /> zone that require an upgrade in level of personal protective equipment (PPE) The action levels apply to all tasks <br /> performed on this site Guidelines for frequency of air monitoring are presented in Table 3-2 <br /> TABLE 3-1 <br /> AIR MONITORING ACTION LEVELS <br /> Instrument* / Function Measurement I Action/Protective E ui ment Required <br /> Photwomzation Detector (PID) or Flame Ionization Detector (FID) - Measures total organic vapors <br /> 0 - 99 ppm Level D <br /> 99 - 499 ppm Upgrade to modified Level D - Half-mask or <br /> full-mask respirator with acid gas/organic vapor <br /> cartridge required <br /> z 500 ppm Stop work Notify PM and RHSO <br /> Oxy en/Ex losimeter (0 /LEL) - Measures oxygen level (0 ) and lower explosive limit (LEL) <br /> 0, 19 5 - 22% 0 Acceptable conditions Continue <br /> normal active <br /> 0 C 19 5% 0 Stop work Notify PM or RHSO <br /> 0, >22% 0 Leave area munediately, this <br /> condition causes extreme fire hazard <br /> 0 Notify PM or RHSO <br /> LEL _<10% 0 Acceptable conditions Continue <br /> normal activity <br /> LEL >10% 0 Leave area immediately <br /> 0 Contact PM or RHSO <br /> * Note Instruinents must be calibrated according to manufacturer's recommendations <br /> 10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.