Laserfiche WebLink
Letter to Wong EnginL_�rs -3- November 1, 1977 <br /> Sheet No. 12 <br /> 1. M.H. frame & cover should be Pinkerton A-163 or equal. <br /> 2. Lateral locations and treatment at property line should conform to <br /> San Joaquin County Ordinance No. 773. <br /> 3. Trench backfill detail upper 3' of backfill 95% relative compaction <br /> is required. <br /> Sheet No. 13 <br /> 1. Control panel wiring diagram will have to be reviewed by San Joaquin <br /> County Building Department prior to this department approving improve- <br /> ment plans. Plan is incomplete. <br /> Sheet No. 14 <br /> 1. Access stairway refabricate to OSHA requirements. <br /> 2. Slab elevation not shown. <br /> Specifications <br /> 1. Specifications and quantities should be revised to reflect any changes <br /> required. <br /> 2. Is a trench shoring bid item required? <br /> 3. Plans and Specifications should be reviewed and approved by San Joaquin <br /> County Counsel. <br /> Please be advised that the plans and specifications should be reviewed and <br /> approved by other departments prior to approval of this department. Special <br /> attention should be made that the plans and specifications conform to the Local <br /> Health District requirements contained in San Joaquin County Ordinance No. 549. <br /> Very truly yours, <br /> WILLIAM J. WARD <br /> DIRECTOR OF PUBLIC WORKS <br /> Henry M. Hirata, P.E. <br /> Principal Engineer <br /> HMH:db <br /> cc: Local Health District <br /> Attn: Lee Hall <br /> Andy Hatfield <br />