Laserfiche WebLink
r <br /> ���� <br /> rr,, <br /> KLE1NFELDER „ r; 21 °+l 2- 39 <br /> November 7, 1988 - <br /> File 24-I119-00 <br /> Mr Dan Clement <br /> City of Stockton <br /> Department of Public Works, Room 317 <br /> 425 North El Dorado <br /> Stockton, CA 95202 <br /> SUBJECT: Soil Sampling Results <br /> 134 S. Sutter Street <br /> Stockton, California <br /> Dear Mr. Clement- <br /> Enclosed are the analytical results for the soil sample collected from under an excavated <br /> tank at 134 S Sutter Street, Stockton, Cahforrua (see Plate 1, Site Location Map). The <br /> sample was collected and submitted for laboratory analyses to assess the possible presence <br /> of petroleum hydrocarbon contamination in the soil beneath the tank. Analytical results <br /> indicate petroleum hydrocarbons are not present in the soil sample <br /> Sam lin, Event Under round Tank <br /> On October 31, 1988, a Kleinfelder field geologist collected one soil sample beneath a <br /> removed 500-gallon underground storage tank. The tank was uncovered during excavation <br /> activities associated with new construction, and the onginal contents of the tank are not <br /> known A representative of San Joaquin Local Health District (SJLHD), Ms Kasev Foley, <br /> was present on October 31, 1988 while work was performed Ms Foley said the (SJLHD) <br /> had the tank listed as a heating oil tank and requested analyses for diesel fuel. Sample <br /> 18149 was collected approximately 15 feet beneath the center of the removed tank The <br /> sample (18149) consisted of a dark red brown silt with approximately 20 percent clay <br /> Voids and root channels were visible throughout the sample No staining or indications of <br /> petroleum hydrocarbons were present to the sample or the soil beneath the removed tank <br /> A sample, collected adjacent to sample 18149, was scanned with a portable flame <br /> ionization detector (FID) There was no response on the FID when this sample was <br /> scanned The former tank location is shown on Plate 2, Sample Location Map <br /> The sample was delivered under chain-of-custody control to Chemwest Analytical <br /> Laboratories, Inc. to Sacramento, California. The sample was analyzed for total <br /> petroleum hydrocarbons (TPH) extractable by GC-FID, and benzene, toluene, <br /> ethvibenzene,Iand xylene (BTEX) by EPA Method 8020 No constituents were detected <br /> above the laboratory reporting limits in the soil sample Copies of the laboratory data <br /> sheets and chain-of-custody form are attached. <br />