Laserfiche WebLink
Site No: 11194 <br /> Groundwater samples were collected from two UST complex observation wells, located on the <br /> southwest and northeast corners of the UST complex (OBS-W and OBS-E, respectively) <br /> (Figure A-1) Both samples were subrrutted for TPH-G, TPH-D, TPH-0, and BTEX analyses <br /> Laboratory results indicated the sample collected from OBS-E contained 370 ppb TPH-O <br /> (Table A-1) <br /> Grab samples were collected from beneath three of the four pump island dispensers (TD-1 <br /> through TD-3),the area beneath the northeastern pump Island contained insufficient material to <br /> sample A PID was used to measure samples collected from TD-1 through TD-3 The sample <br /> from TD-2 registered a reading of 45 ppm on the PID, the samples from TD-1 and TD-3 did <br /> not register readings on the PID <br /> The sample from TD-2 was submitted for TPH-G, TPH-D, TPH-O, and BTEX analyses <br /> Laboratory results indicated the sample contained TPH-G (270 ppm), TPH-D (10,000 ppm), <br /> ethylbenzene (0 2 ppm) and total xylenes (2 4 ppm,Table A-1) <br /> i <br />. BrrOS/RPT/I I 194RPTd I 2-94/JLJ/smw 6 Rey 0 02/03195 <br /> 0952-09203 <br /> 2 <br />