Laserfiche WebLink
1 . `t <br /> ®' Eovu..G.Snow.JR. <br /> mu+non <br /> •u r e x x u Mnrnew RooRiov[z <br /> Water Boards : �' ..°craw.[=r,=- <br /> Central Valley Regional Water Quality Control Board <br /> 14 July 2014 <br /> Dennis Leikem <br /> Environmental Manager <br /> Musco Family Olive Company <br /> 17950 Via Nicolo <br /> Tracy, CA 95377 <br /> APPROVAL OF WORK PLAN ADDENDUM TO INSTALL GROUNDWATER MONITORING <br /> WELLS, MUSCO FAMILY OLIVE COMPANY, SAN JOAQUIN COUNTY <br /> The Central Valley Water Board has reviewed the Work Plan Addendum to install a replacement <br /> well, required for the new Class II surface impoundments for the Detection Monitoring System at <br /> the Musco facility. At this time, Musco has installed three groundwater monitoring wells MW-33, <br /> MW-34, and MW-35 to address the requirement of Title 27, Section 20415(b)(B) to have: a <br /> sufficient number of Monitoring Points installed at appropriate locations and depths to yield <br /> groundwater samples from the uppermost aquifer that represent the quality of groundwater <br /> passing the Point of Compliance and to allow for the detection of a release from the Unit. <br /> The work plan addendum proposes to reinstall well MW-35, to accommodate the redesigned <br /> foot print of the proposed Class II surface impoundments (i.e. Ponds C and D). Replacement <br /> well MW-35R is proposed to be located downgradient of the Pond D sump. MW-35R will be <br /> drilled and constructed to a depth that mirrors well MW-35. All well drilling, construction detail, <br /> and permitting requirements will be performed in accordance with the revised Work Plan dated <br /> 9 December 2013. <br /> Staff and Musco participated in a teleconference on 8 July 2014 to discuss the work plan <br /> addendum. It is staffs understanding that well MW-35 has been destroyed in accordance with <br /> the 8 May 2014 work plan addendum and that pond construction could begin the week of 7 July <br /> 2014. It was agreed during the teleconference that the proposed location of well MW-35R <br /> would be drilled as close to the location of former well MW-35, at the toe of the berm of Pond D. <br /> However, well MW-35R will not be installed until the berms of Pond D are constructed. This <br /> would allow the location of well MW-35R to be pin-pointed as close as possible to the former <br /> location of well MW-35 in hopes of providing a higher level of confidence of finding the <br /> underlying water bearing zone previously identified. <br /> Furthermore, the work plan addendum also proposes to install two piezometers. One <br /> piezometer would be installed west of Pond D and one would be installed east of Pond D. The <br /> reasoning for these piezometers is to establish a three well Detection Monitoring Program <br /> (DMP) that would provide groundwater flow direction and gradient for the water bearing zone <br /> identified at MW-35. Musco proposes to construct the piezometers with 2-inch diameter PVC <br /> KARL E. LONGLEv ScD, P.E..CHAIR I PAMELA C. CREEOOH P.E., BCEE,EAECUrIVE OFFICER <br /> 11020 Sun Center Drive#200.Rancho Cordova.CA 95670 1 www.waterboards.ce.gov/controlvelley <br /> �#RLcm[[o n.oeR <br />