My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WASHINGTON
>
1340
>
2200 - Hazardous Waste Program
>
PR0505945
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/2/2025 1:04:53 PM
Creation date
6/3/2020 9:04:16 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0505945
PE
2220
FACILITY_ID
FA0007099
FACILITY_NAME
DURAFLAME WEST
STREET_NUMBER
1340
Direction
W
STREET_NAME
WASHINGTON
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
14530012
CURRENT_STATUS
01
SITE_LOCATION
1340 W WASHINGTON ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\HW\HW_2220_PR0505945_1340 W WASHINGTON_.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
301
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
§ 66265.33 BRAYS CALIFORNIA CODE. OF REGUIANS Title 22 <br />(d) water at adequate volume and pressure to supply water hose <br />streams. or foam quipment. Or automatic sprinklers, or water <br />spray systems. <br />NOTE: Authority cited: Sections 208, 25150 and 25159. Health and Safety Code. <br />Reference: Sections 25159 and 25159.5, Health and Safety Onle: 40 CFR Section <br />265.32. <br />HISTORY <br />New section filed 5-24-91: operative 7-1-91 (Register 91. No. 22). <br />66265.33. Testing and Maintenance of Equipment. <br />All facility communications or alarm systems. fire protection equip <br />ment. spill control equipment, and decontamination equipment. where <br />required, shall be tested and maintained as necessary to assure its proper <br />Operation in time of emergency. <br />NOTE: Authority cited: Sections 208, 25150 and 25159. Health and Safety Code. <br />Reference: Sections 25159 and 25159.5. Health and SafetyCode: 40CFR Section <br />26533. <br />HISTORY <br />1. New section filed 5-24-91: operative 7-1-91 (Register 91. No. 22). <br />§66265.34. A660Lift-munlcations or Alarrn System. <br />(a) Whenever hazardous waste is being poured, mixed. spread. or <br />otherwise h sonnei involved in the operation shall have im- <br />mediateaccesst6 m`temalalarm oremergency communicationdevice. <br />either directly or through visual or voice contact with another employee. <br />unless the Department has ruled that such a device is not required under <br />section 66265.32. <br />(b) If there is ever just one employee on the premises while the Facility <br />is operating, the employee shall have immediate access to a device, such <br />as a telephone (immediately available at the scene of operaticxi) or a <br />hand-held two-way radio. capable of summoning external emergency <br />assistance, unless the Department has ruled dial such a device is not re- <br />quired under section 66265.32. <br />NOTE: Authority cited: Sections 208. 251.50 and 25159. Health and Safety Code. <br />Reference: Sections 25159 and 25159.5. Health and SafetyCode: 40 CFR Section <br />256.34. <br />HISTORY <br />New section filed 5-24-91: operative 7-1-91 (Register 91. No. 22). <br />66265.35. Required Aisle Space. <br />The owner or operator shall maintain aisle space to allow the unob- <br />structed movement of personnel. fire protection equipment. spill control <br />equipment. and decontamination equipment to any area of facility opera- <br />tion in an emergency, unless it can be demonstrated to the Department <br />that aisle space is not needed for any of these purposes. <br />NOTE: Authority cited: Sections 208, 25150 and 25159. Health and Safety Code. <br />Reference: Sections 25159 and 25159.5. Health and Safety Code: 40CFR Section <br />265.35. <br />HISTORY <br />New section filed 5-24-91: operative 7-1-91 (Register 91, No. 22). <br />:t 66265.37. Arrangements with Local Authorities. <br />(a)'Ihe owneroroperator shall attempt to make the following arrange- <br />ments. as appropriate. for the type of waste handled at die facility and the <br />potential need for the services of these organizations: <br />(1) arrangements to familiarize police, fire departments. emergency <br />response teams. and the local Office of Emergency Services with the lay- <br />out of the facility, properties of hazardous waste handled at die facility <br />and associated hazards, places where facility personnel would normally <br />be working, entrances toroads inside the facility, and possible evacuation <br />routes. <br />(2) where more than one police and fire department might respond to <br />an emergency. agreements designating primary emergency authority to <br />a specific police and a specific fire department. and agreements with any <br />others to provide support to the primary emergency authority: <br />(3) agreements with State emergency response teams. emergency re- <br />sponse contractors. and equipment supplies: and <br />(4) arrangements to familiarize local hospitals with the properties of <br />hazardous waste handled at the facility and the types of inptries or ill- <br />nesses which could result from fires, explosions. or releases at the facil- <br />ity. <br />(b) Where State or local authorities decline to enter into such arrange- <br />merits. the owner or operator shall document die refusal in the operatic <br />record. <br />Now: Authority cited: Sections 208.25150 and 25159. Health and Safety Code. <br />Relerence: Sections 25159 and 25159.5. Health and Safety Code: 40CFR Section <br />265.37. <br />HISTORY <br />1. New section filed 5-24-91: opeiative 7-1-91 (Register 91, No. 22). <br />Article 4. Contingency Plan and <br />Emergency Procedures <br />66265.50. Applicability. <br />llie regulations in this article apply toowners and operators of all haz- <br />ardous waste facilities. except as section 66265.1 provides otherwise. <br />Noir.: Authority cited: Sections 208, 25150 and 2.5159, Health and Safety Code. <br />Reference: Sections 25159 and 25159.5. Health and Safety Code: 40CFR Section <br />265.50. <br />HISTORY <br />1. New section filed 5-24-91: operative 7-1-91 (Register 91. No. 22). <br />66265.51. Purpose and Implementation of Contingency <br />Plan. <br />(a) Each owner or operator shall have a contingency plan for the facil- <br />ity. 'llie contingency plan shall be designed to minimize hazards to hu- <br />man health or the environment from fires, explosions. or any unplanned <br />sudden or non -sudden release of hazardous waste or hazardous waste <br />constituents to air. soil, or surface water. <br />(b) the provisions of the plan shall be carried out immediately when- <br />ever there is a fire. explosion. or release of hazardous waste or hazardous <br />waste constituents which could threaten human health or die envirm <br />ment. ; <br />NOTE: Authority cited: Sections 208.25150 and 25159. Health and Safety Code. <br />Reference: Sections 25159 and ZS 159.5. Health and Safet_vCode:40 CFR Section <br />265.51. <br />HISTORY <br />1. New section filed 5-24-91: operative 7-1-91 (Register 91. No. 22). <br />§ 66265.52. Content of Contingency Plan. <br />(a) 'ilhe contingency plan shall describe die actions facility personnel <br />shall take to comply with sections 66265.51 and 66265.56 in response to <br />fires, explosions. or anyunplanned sudden ornon-sudden release of haz- <br />ardnus waste or hazardous waste constituents to air. soil, or surface water <br />at die facility. <br />(b) If die owner or operator has already prepared a Spill Prevention. <br />Control. and Countermeasures (SPCC) Plan in accordance with 40 CFR <br />Part 112. or 40 CFR Part 1510. or some other emergency or contingency <br />plate. the owner or operator need only aniend that plan to incorporate haz- <br />ardous waste management provisions that are sufficient to comply with <br />the requirements of this chapter. <br />(c)1he plan shall describe arrangements agreed to by local police de- <br />partments, fire departments, hospitals, contractors, and State and local <br />emergency response teams to coordinate emergency services, pursuant <br />to section 66265.37. <br />(d) The plan shall list names, addresses, and phone numbers (office <br />and home) of all persons qualified to act as emergency coordinator (see <br />section 66265.55), and this list shall be kept up to date. Where more than <br />one person is listed, one shall be named as primary emergency coordina- <br />tor and others shall be listed in the order in which they will assume re- <br />sponsibility as alternates. <br />(e) The plan shall include a list of all emergency equipment at the fac." <br />ity (such as fire extinguishing systems, spill control equipment. comni <br />nications and alarm systems (internal and external), and decontaminathott- <br />equipment). where this equipment is required. This list shall be kept up <br />to date. in addition. the plan shall include die location and a physical de- <br />scription of each item on die list, and a brief outline of its capabilities. <br />Page 758.54(1) Regime 06.N-5 7:2-16-Q6 <br />