My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
1120
>
2200 - Hazardous Waste Program
>
PR0513661
>
COMPLIANCE INFO_2010-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/23/2021 9:52:05 AM
Creation date
6/3/2020 9:20:55 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0513661
PE
2227
FACILITY_ID
FA0009133
FACILITY_NAME
BELKORP AG - STOCKTON
STREET_NUMBER
1120
Direction
W
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206-0020
APN
16320021
CURRENT_STATUS
01
SITE_LOCATION
1120 W CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\HW\HW_2227_PR0513661_1120 W CHARTER_.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
367
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Ab- <br /> San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sjgov.org/ehd <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Belkor A -Stockton 1120 W CHARTER WAY STOCKTON October 22 2015 <br /> Universal Waste <br /> 705 CCR 66273.33(c) Failed to properly manage mercury containing universal waste ❑V ❑R ❑COS <br /> 706 CCR 66273.33.5 Failed to properly manage universal waste electronic devices,CRTs or CRT glass ❑V ❑R ❑COS <br /> 707 HSC 25201.16(e) Failed to manage aerosol cans in a manner that prevents the unauthorized release of waste ❑V ❑R ❑COS <br /> 708 HSC 25201.16(f) Failed to properly manage containers of waste aerosol cans ❑V ❑R ❑COS <br /> 709 HSC 25201.16(g) Failed to store used aerosol cans in an accumulation container ❑V ❑R ❑COS <br /> 710 HSC 25201.16(h)(4) No written operating procedure for aerosol can processing ■V ❑R ❑COS <br /> 711 HSC 25201.160) Failed to submit or amend notification for aerosol can processing ■V ❑R ❑COS <br /> 712 CCR 66273.34 Failed to label universal waste to identify type of universal waste ❑V ❑R ❑COS <br /> 713 CCR 66273.35 Stored UW onsite greater than one year or was unable to demonstrate the time UW has been stored ❑V ❑R ❑COS <br /> 714 CCR 66273.36 Failed to train employees and maintain records on UW handling and emergency procedures ❑V ❑R ❑COS <br /> 715 CCR 66273.39 Failed to keep complete records of each shipment of universal waste for three years ❑V ❑R ❑COS <br /> Other Violations <br /> 3010 See below Unlisted Administration/Documentation violation ❑V ❑R ❑COS <br /> 3020 See below Unlisted Training violation ❑V ❑R ❑COS <br /> 3030 See below Unlisted Operations/Maintenance violation ❑V ❑R ❑COS <br /> 3040 See below Unlisted Release/Leaks/Spills violation ❑V ❑R ❑COS <br /> 3050 See below Unlisted Abandonment/Illegal Disposal/Unauthorized Treatment violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 102 CCR 66262.11, 66262.40(c) Failed to determine if a waste is a hazardous waste or retain waste analysis on site for 3 <br /> years. <br /> Oily absorbent was observed in the trash cans in the ag shop. Any person who generates a waste shall determine if <br /> the waste is a hazardous waste. Immediately remove all oily absorbent from the trash, make a hazardous waste <br /> determination for the oily absorbent waste, and manage it according the Title 22 hazardous waste regulations. Submit <br /> a statement and supporting documentation explaining how this waste was managed. <br /> This is a minor violation. <br /> 103 CCR 66262.34(d)(2) No modified contingency plan. <br /> An emergency coordinator and modified contingency plan information is lacking. There must be at least one <br /> emergency coordinator on site or on call to coordinate emergency response measures, and the following information <br /> must be posted by a phone: the name and phone number of the emergency coordinator; location of fire extinguishers, <br /> spill control equipment, and if present, fire alarm; and the phone number of the fire department, unless the facility has <br /> a direct alarm. Immediately appoint an emergency coordinator and post the required information by a phone. A form <br /> is provided that can be used for this purpose. <br /> This is a minor violation. <br /> Received by <i ,l —� Inspector: Phone: Date: <br /> (initial): STACY RIVERA, Senior REHS (209) 468-3440 10/22/2015 <br /> Page 3of8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.