My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2004-2005
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COUNTRY CLUB
>
2575
>
2300 - Underground Storage Tank Program
>
PR0231070
>
COMPLIANCE INFO_2004-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/30/2023 2:30:02 PM
Creation date
6/3/2020 9:43:34 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2004-2005
RECORD_ID
PR0231070
PE
2351
FACILITY_ID
FA0006439
FACILITY_NAME
COUNTRY CLUB MOBIL CIRCLE K
STREET_NUMBER
2575
STREET_NAME
COUNTRY CLUB
STREET_TYPE
BLVD
City
STOCKTON
Zip
95204
CURRENT_STATUS
01
SITE_LOCATION
2575 COUNTRY CLUB BLVD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2351_PR0231070_2575 COUNTRY CLUB_2004-2005.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
531
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Primary Piping System Installation <br /> PE P ttS other material from getting into the pipe. <br /> Fittings and adhesives should be stored <br /> RED T IIA in a dry area. If fittings are re- <br /> Epoxy pipe that is lightweight and pro- moved from the boxes,protect <br /> vides long service life and corrosion resis- machined bells and spigots from <br /> tance. UL/ULC Listed piping is available in exposure to direct sunlight. <br /> 2"-4"primary pipe sizes and 3"-4"contain- <br /> ment pipe sizes. Non-ULIULC Listed con- $ Storing <br /> tainment piping is available in 6"-16"diame- You can safely store bundles on level <br /> ters.T.A.B. (Threaded and Bonded bell& ground or on racks with 10 foot(3 m)or less support spacing. <br /> spigot)is the primary joining method for the ,ovoid point loads. Use supports with a minimum of four-inch <br /> pipe.Pipe comes in 15,25 and 30 foot random lengths. (100 m) wide bearing <br /> area to prevent damage to _ <br /> the pipe. Do not store on <br /> FITTINGS rocks or other hard objects <br /> that could cause pointkl <br /> - <br /> Smith Fibercast UL/ULC Listed primary fittings are green. loading damage. When <br /> l outdoor storage is reEll <br /> - <br /> '4di s; quired,check to see that <br /> 4i1F <br /> the pipes'protective end caps <br /> are in place to protect the spigots and insides of <br /> the bells from weathering. Use black polyethylene or other <br /> ultraviolet ray blocking material to cover all factory-prepared <br /> bonding surfaces if end caps are missing or not available. <br /> C. Transporting <br /> Use reasonable care in handling the pipe and fittings. <br /> When transporting from storage to the job site,do not allow <br /> pipe to extend more than 10 feet(3 m)beyond the end of the <br /> Clam shell secondary containment fittings are blue. truck or trailer bed; permanent damage can result from ex- <br /> cessive bending stress. Protect pipe to prevent impact and <br /> point-loading damage. NOTE: During transport,strap the <br /> pipe down with nylon or <br /> hemp rope tie downs. <br /> This will help prevent <br /> abnormal movement of <br /> the pipe during trans- <br /> portation. Wood or <br /> padded supports are <br /> essential for truck or <br /> STORAGE-' trailer beds that have <br /> sharp edges(such as metal plates on the back of a flat-bed <br /> A. Packaging,Ordering and Shipping Information trailer). When transporting the pipe on trucks with narrow <br /> Pipe comes in 15,25 and 30 ft.(5,7.6 and 9.2 meter)ran- overhead piping racks(11h"to 2"/40mm to 50mm in width or <br /> dom lengths. The number of lengths per bundle varies with diameter),it is essential that padded supports be used to pre- <br /> the pipe diameter. Two-inch pipe is supplied with a protective vent point loads. If chains are used during transport,they <br /> mesh covering. must also be well-padded to prevent damage to pipe walls. <br /> TABLE 1.Standard Packaging of Pipe D. Loading and Unloading <br /> Pipe Size Random Length Lengths When the pipe is not specially packaged, it should be <br /> loaded and unloaded by hand. When properly palletized or <br /> (in.) (mm) (ft.) (m) Per Bundle otherwise adequately protected,foridifts may be used. <br /> 2 50 15,25 or 30 5,7.6 or 9.2 8 Do not throw or drop pipe and/or fit- <br /> 3 75 15,25 or 30 5,7.6 or 9.2 6 tings from the truck to the ground. <br /> 4 100 15,25 or 30 5,7.6 or 9.2 4 Protect pipe and fittings from <br /> point-loading or impact damage <br /> at all times. <br /> Smith Fibercast pipe is furnished factory packaged in <br /> compact,easy-to-handle bundles complete with protective <br /> end caps. Leave these caps in place until installation <br /> time to protect the pipe ends as well as to prevent dirt or <br /> 1 Installation Instructions <br />
The URL can be used to link to this page
Your browser does not support the video tag.