Laserfiche WebLink
03/02/2012 03:38 9252920074 GDF_SOLUTIONS FAX PAGE 08/15 <br /> UNDERGROUND STORAGE TANK <br /> RESPONSE PLAN PAGE 2 <br /> VI. REPORTING AND RECORD KEEPING <br /> We will repordrecord any overfill,spill,or unauthorized release from a UST system as indicated in this plan, <br /> Recordable Releases: Any unauthorized relem from primary containaent which the UST operator is able to clean up within eight(S)hours rifler the release was <br /> detected or should reasonably have been detecuod,and which does not escape Sohn secondary containment,does not increase the hazard of fire or explosion.and does <br /> not cause any deterioration of Monday containment,must be recorded in the Mlity's monitoring records. MeatiRoring records mast include <br /> > De UST Mar's name and telephone number, <br /> > A list of the types,quantities,and concentrations of hazardous substances released; <br /> A A description of the actions taken to control std clean up the release; <br /> > The method and location of disposal of the released hazardous substances,and whether a hazardous waste manifest was or will be used; <br /> > A descrOon of notions W=to repair the UST and to prevent future rcimes; <br /> D A description of the method used to reactivate interstitial monitoring after replacement or repair oforru ry contairtawt. <br /> Reportable Releases: Any overfill,spill,or unauthorized mieasc whiter escapes from secondary containment(or primary contaigment if no secondary containment <br /> exists),increa4ra the hazard of fire or explosion,or causes any deterioration of secondary containment,is a reportable rcleasa Reportable releases are also recordable. <br /> Within 24 house alter a reportable release has been detected.or should have been detected,we will notify the beat agency administering the UST program of the <br /> release,investigato the rolgase,and telco immediate treasures to stop the rekasc. If necessary,or if required by the local agency,remaining stored product/waste will <br /> be removed fitmt rte UST to prevent furuer releases or facilitatc corrective action. tf an emergency exists,we will notify ft State Office of Emergency Service, <br /> Within five(5)working days of a reportable release,we will submit to the Iocal agency a full written report containing all of the following information to the extent <br /> that tine inftrnatin is known at the tinne of filing the report <br /> > The UST ownces or opetetor's natre and telephone number, <br /> > A list of the typm quawatities,and concentrations of hazardous materials released; <br /> > The approximate date of the repose; <br /> D The date on which due release was discovered; <br /> > The date on which the release we stopped; <br /> > A description of actions taper to control and/or stop the release; <br /> > A descxiptrorn of rorradve and remedial aeti=6 including inywiggions which were wulertaken and Will bo conducted to determine tate nature and extort of <br /> soil,ground water or sudor water contamination due to the release; <br /> D The methods)of cleanup implemented to date,proposed cleanup sedans,and a schedule for implementing the proposed actions; <br /> > The )and beatiot(s)of disposal of released hazardous mauls and any contaminated soils,grotardwazer,or sur flue water. <br /> A Copies of any hazardous weste manifests used for off-site transport of hm;ardors wastes Associated with c1cm-up Activity. <br /> > A desmiption of proposed methods for any repair or replacement of UST system primary/secondary containment <br /> A A description of additional action wJwn to prevent Erman relaxes. <br /> We will follow the reporting procedures described above if any of the following conditions occur: <br /> > A recordabie unauthorized release can not be cleaned up or is still under investigation within eight(g)hours of detection; <br /> > Released hazardous substances are discovered at the UST site or in the surrounding area; <br /> > Unusual operating cnnditiars are observed,including aratio behavior of product dispensing equipment,sudden lass of product,or the unexplained presence of <br /> water in the reale,amore system equipment is found to be defective and is immediately mpaired or replaced.and no leak has <br /> > Monitoring results from UST system monitoring equipmenVinethods indicate that a ruse may have occurred,unless the nnmuforing equipment is found to be <br /> defective and is immediately repaired,recalibrated.or replaced,and additional monitoring does not confirm the initial malts. <br /> Record Retention: Monitoring records sari written reports of unauthorized releases mast be maintained on-site(or off-site at a roily available location,if approved <br /> by the local agtmy)for at least 3 years. Hazardous waste shipping/disposal records(e.g..matifew)must be maintained for at tarsi 3 years from the date of shiptreK <br /> VR. O'WNERIOPERATOR SIGNATURE <br /> CTRTIFt QNa t certify that th for madon provided her'tin is true and aecumte to the but of my kwMtdgs. <br /> OWNS ERATOR SICiNA BATS a70• <br /> February 2,2012 <br /> OWNER/OPERATOR NAME t) sit. OWNER/OPEPATOR TiTLE R72 <br /> Mike Ahlaadi (Dealer <br /> (Agency Ura Only) This pl r cd y cd ❑Approved With Conditions (7 Disapproved <br /> Local Agency Signature Date" /'3 9 <br /> UST Response Plan(3/M)3/3 <br />