My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2002-2005
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BENJAMIN HOLT
>
2908
>
2300 - Underground Storage Tank Program
>
PR0231021
>
COMPLIANCE INFO_2002-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/22/2022 11:56:42 AM
Creation date
6/3/2020 9:44:18 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002-2005
RECORD_ID
PR0231021
PE
2361
FACILITY_ID
FA0003625
FACILITY_NAME
ARCO STATION #83560*
STREET_NUMBER
2908
Direction
W
STREET_NAME
BENJAMIN HOLT
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
09763032
CURRENT_STATUS
01
SITE_LOCATION
2908 W BENJAMIN HOLT DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231021_2908 W BENJAMIN HOLT_2002-2005.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
435
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
f Page 5 of <br /> 7.U R-DISPENSER CONTAINMENT(UP TESTING <br /> Test Method Developed By: UDC Manufacturer ❑ Industry Standard M Professional Engineer ❑ <br /> Other(Specify) <br /> Test Method Used: Pressure ❑ Vacuum ❑ Hydrostatic M <br /> Other(Specify) <br /> Test Equipment Used: Wayne Perry Inc. See Attached Testing Results Equipment Resolution: .00007 <br /> Under-Dispenser Containment Number Below <br /> ,3 - — <br /> rUDCanufacturer: 10co-S <br /> UDC Material <br /> UDC Depth: <br /> Height from UDC Bottom to Tog <br /> of Highest Piping Penetration: 5� <br /> Height from UDC Bottom to <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to <br /> testing: <br /> Portion of UDC Tested' 2"Above Highest 2"Above Highest 2"Above Highest 2"Above Highest <br /> Penetration Penetration Penetration Penetration <br /> Does turbine:shut down when ❑Yes❑ No NA® ❑ Yes❑ No NA® ❑Yes❑ No NA® ❑Yes❑ No NA® <br /> UDC sensor detects liquid. <br /> Turbine shutdown response time ❑Yes❑ No NAZ ❑Yes❑ No NA® ❑Yes❑ No NA® ❑Yes❑ No NA® <br /> Is system programmed for fail- ❑Yes❑ No NAN ❑Yes❑ No NA® ❑Yes❑ No NA® ❑Yes❑ No NAM <br /> safe shutdown?` <br /> Was fail-safe verified to be ❑Yes❑ No NA® ❑ Yes❑ No NA® ❑Yes❑ No NA.® ❑Yes❑ No NA® <br /> operational?* <br /> Wait time between applying <br /> pressure/vacuum/water and 15 Minutes 15 Minutes 15 Minutes 15 Minutes <br /> starting test <br /> Test Start Time: 11,77 �`.``� /'Z,r7 /Z'2 v <br /> Initial Reading(RI): ,17/Z /f"S 2 O "9SA 0 A zo 2 <br /> Test End Time: 1/,151 l;33 /2:3Z. /7:35 <br /> Final Reading(RF): f0 •S ZZ •�� /z® <br /> Test Duration: 15 Min 15 Min 15 Min 15 Min 15 Min 15 Min 15 Min 15 Min <br /> Change in Reading(RF-RI): ,080 �,Pa ®d d f 0 ,mo ya <br /> Pass/Fail Threshold or Criteria: -0.0020 -0.0020 -0.0020 -0.0020 -0.0020 -0.0020 -0.0020 -0.0020 <br /> Test Resc> tF 7777M <br /> 7.7 <br /> "slss Pass ]1 � �� � 3 <br /> Was sensor removed for testing? ❑Yes❑ No NA❑ ❑Yes❑ No NA❑ ❑Yes❑ No NAE] ❑Yes❑ No NAE] <br /> Was sensor properly replaced and ❑Yes❑ No NAE] ❑Yes❑ No NAE] ❑ Yes❑ No NAE] ❑Yes❑ No NA❑ <br /> verified functional after testing?, <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />