My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2002-2005
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BENJAMIN HOLT
>
2908
>
2300 - Underground Storage Tank Program
>
PR0231021
>
COMPLIANCE INFO_2002-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/22/2022 11:56:42 AM
Creation date
6/3/2020 9:44:18 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002-2005
RECORD_ID
PR0231021
PE
2361
FACILITY_ID
FA0003625
FACILITY_NAME
ARCO STATION #83560*
STREET_NUMBER
2908
Direction
W
STREET_NAME
BENJAMIN HOLT
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
09763032
CURRENT_STATUS
01
SITE_LOCATION
2908 W BENJAMIN HOLT DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231021_2908 W BENJAMIN HOLT_2002-2005.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
435
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 6 of / <br /> 8. OL RISER CONTAINMENT SUMP TIANG <br /> Facilit is Not Equipped With Fill Riser Containment Sums ❑ <br /> Fill Riser Containment Sumps are Present,but were Not Tested ❑ <br /> Test Method Developed By: ❑Sump Manufacturer ® Industry Standard ❑Professional Engineer <br /> ❑Other(Specify) <br /> Test Method Used: ❑Pressure ❑ Vacuum ®Hydrostatic <br /> ❑Other(Specify) <br /> Test Equipment Used: Wayne Perry Inc. See Attached Results Equipment Resolution: WO7" <br /> Sump# Sump -V/f "-e Sump# Sump# <br /> Sump Diameter: <br /> Sump Depth:`✓ 7 <br /> Sump Material: 'z'_ <br /> Height from Tank Top to Top of » <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest H- <br /> Electrical Penetration: 12 <br /> Condition of sump prior to testing: _-'" <br /> Portion of Sump Tested11` 2"ABOVE HIGHEST 2"ABOVE HIGHEST 2"ABOVE HIGHEST 2"ABOVE HIGHEST <br /> PENETRATION PENETRATION PENETRATION PENETRATION <br /> Wait time between applying water 15 Minutes 15 Minutes 15 Minutes 15 Minutes <br /> and starting test: _ <br /> Test Start Time: <br /> Initial Reading(R1): �'� 68 ,6 <br /> Test End Time: la"30 <br /> Final Reading(RF): 4014o/ <br /> Test Duration: 15 Min 15 Min 15 Min 15 Min 15 Min 15 Min 15 Min 15 Min <br /> Change in Reading(RF-RD: ,per <Eeo/Z (,0,003` <br /> Pass/Fail Threshold or Criteria: ` -0.0020 -0.0020 -0.0020 -0.0020 -0.0020 -0.0020 -0.0020 -0.0020 <br /> Is there a sensor in the sump? ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> Does sensor alarm when either ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> product or water is detected? <br /> Was sensor removed for Testing? ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> =sensor replaced and ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> fter testing? <br /> Comments-(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> Arco #2133 <br /> 2908 W. Benjamin Holt Dr. <br /> Stockton, CA. 95207 <br /> N05127 —SB 989 Testing <br />
The URL can be used to link to this page
Your browser does not support the video tag.