Laserfiche WebLink
11/30/2004 11:53 2094683433 FIFTH FLOOR PAGE 08 <br /> MINIMUM VERIFICATION LABORATORY ANALYSIS <br /> OXYGEN <br /> TANK TANK TPH-G TPH-D BTX&E CL HC TOTAL MTBE ATES METAL PCB <br /> CONTENTS 8015 8015 800 8010 LEAD 8020 (KME, ICRP/ 8270 <br /> 8260 8260 8260 8240 7420 8260 TRADIPE. AES or 8080 <br /> $260 7421 ETBF- AA <br /> TAME) <br /> 8260 <br /> LEADED GAS X X X X <br /> LJNL GAS X X X <br /> DIESEL X X <br /> KEROSENE X X X <br /> UNK <br /> FUEL X X X X X <br /> PROD, OIL X X X <br /> CHLOR. X <br /> SOLVENTS X X <br /> NONCHLOR X <br /> SOLVENTS X X <br /> NVASTE\ <br /> USED OIL X X X X X X X <br /> All analysis methods are the designated EPA methods&wnbed in SW 946,Third Edition. Those methods not found in SW 846 are <br /> specifically noted below. Refer to the"SNMCB LLTFT Field Manual",Appendix D(B),Table 3-5 on page A20 for minimumdetection <br /> limits for motor vehicle fuel (gasoline and diesel). Refer to -Tri-Regional Board Staff Recommendations for Initial Evaluation and <br /> Investigation of UST's"for the waste and motor oil mininiun detection bruits. Detection Limits that remain below the MCI,,STLC or <br /> Allowable Lintit pf the contaminant in question will be accepted,however taborqtory shall utilize the most conservative method. <br /> LABORATORY ANALYSES TERMINOLOGY: <br /> TPH-G Total Petroleum Hydrocarbon,Gasoline,GCIFID(5030)9015 mod orGC(MS 8260 <br /> TPH-D Total Petroleum Hydrocarbon,Diesel,CYCIFID(3550),8015 mod orGCJMS 8260 <br /> BTX&E Benzene,Toluene,Xylene&Ethyl Benzene,GC(Pll)8020 or ODMS 8260 <br /> CL HC Chlorinated Hydrocarbon,GC(HSDBOIO,GCfMS8240or8260 <br /> TOTAL LEAD Total lead,A.A.7420, AA 7421 or ICP-AES 6010 <br /> OX-yagNATES MTBE,ETBE,TAME,DIPS,&TBA GC/MS 8260(For MTBE screen only you may use 8020) <br /> METALS ICRP or AA Inductively Coupled Plasma Atomic Emission Spectranxtry 6010 or Atomic Absorption Spectrometry 7000. Metals: <br /> Cadminn4 Chromium III and VI,Lead,Zine and Nidwl. <br /> pcZ Polychlorinated Biphenyls,GC/MS 9270 or 8080 <br /> GC-FID Gas Chromatography,Flame Ionization Detection <br /> Method 3050 Acid digestion <br /> Method 3540 Soxhlet sample preparation <br /> Method 3550 Sonication sample preparation,extraction method <br /> Method 5030 Purge and trap sample preparation <br /> QA/QC Quality Assurance/Quality Control <br /> Notes: To avoid false positive detection of benzene,benzene-fret solvents are to be used. Fused capillary columns at preferred to packed columns;a <br /> packed column may be used as a"first cut"with"dirty"samples or once the hydrocarbons have bccn characterized and proper QAJQC is followed. For <br /> drinking water sources,EPA recommends that the 500 series for volatile organic should be used in preference to the 600 series because the detection <br /> limits are lower and the QA/QC is better. Samples exhibiting any level otheavy metal contamination may require ffirther analysis.PHS-EHD <br /> recommends holding those samples until disposal is indicated. <br /> EH 23 046 (Revised 05/09/00) <br />