UCSB04N - SS#2705448 Page 5 of 7 <br />7. UNDER -DISPENSER CONTAINMENT C TESTING <br />Test Method Developed By: ❑ UDC Manufacturer N Industry Standard ❑ Professional Engineer <br />❑ Other (Specify) <br />Test Method Used: ❑ Pressure ❑ Vacuum N Hydrostatic <br />❑ Other (Specify) <br />Test Equipment Used: INCON TS -STS TEST UNIT <br />Equipment Resolution: <br />UDC # 1-2 <br />UDC # 3-4 <br />UDC # 5-6 <br />UDC # 7-8 <br />UDC Manufacturer: <br />BRAVO <br />BRAVO <br />BRAVO <br />BRAVO <br />UDC Material: <br />FIBERGLASS <br />FIBERGLASS <br />FIBERGLASS <br />FIBERGLASS <br />UDC Depth: <br />31" <br />31" <br />31" <br />31" <br />Height from UDC Bottom to Top <br />of Highest Piping Penetration: <br />16" <br />16" <br />15 '/2" <br />16" <br />Height from UDC Bottom to <br />Lowest Electrical Penetration: <br />20" <br />15" <br />16" <br />15 '/2" <br />Condition of UDC prior to <br />testing: <br />GOOD <br />GOOD <br />GOOD <br />GOOD <br />Portion of UDC Tested <br />2" ABOVE HIGHEST <br />PIPING PENETRATION <br />2" ABOVE HIGHEST <br />PIPING PENETRATION <br />2" ABOVE HIGHEST <br />PIPING PENETRATION <br />2" ABOVE HIGHEST <br />PIPING PENETRATION <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />product and water)? <br />NO <br />NO <br />NO <br />NO <br />Turbine shutdown response time <br />NA <br />NA <br />NA <br />NA <br />Is system programmed for fail- <br />safe shutdown?* <br />❑ Yes N No ❑ NA <br />❑ Yes N No ❑ NA <br />❑ Yes N No ❑ NA <br />❑ Yes N No ❑ NA <br />Was fail-safe verified to be <br />operational?* <br />❑ Yes ❑ No N NA <br />❑ Yes ❑ No N NA <br />❑ Yes ❑ No N NA <br />❑ Yes ❑ No N NA <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test <br />15 MINUTES <br />15 MINUTES <br />15 MINUTES <br />15 MINUTES <br />Test Start Time: <br />12:27 12:42 <br />12:27 12:42 <br />1:58 2:14 <br />1:58 2:14 <br />Initial Reading (RI): <br />2.914 2.913 <br />6.069 6.069 <br />7.102 7.102 <br />4.042 4.040 <br />Test End Time: <br />12:42 12:58 <br />12:42 12:58 <br />2:13 2:29 <br />2:13 2:29 <br />Final Reading (RF): <br />2.913 2.913 <br />6.069 6.069 <br />7.102 7.101 <br />4.042 4.041 <br />Test Duration. <br />15 MIN 15 MIN <br />15 MIN 15 MIN <br />15 MIN 15 MIN <br />15 MIN 15 MIN <br />Change in Reading (RF -RI): <br />-0.001 0.000 <br />0.000 0.000 <br />0.000 -0.001 <br />0.000 +0.001 <br />Pass/Fail Threshold or Criteria: <br />-0.002 -0.002 <br />-0.002 -0.002 <br />-0.002 -0.002 <br />-0.002 -0.002 <br />Test Result: <br />N Pass ❑ Fail <br />N Pass ❑ Fail <br />N Pass', ❑ Fail <br />N Pass ❑ Fail <br />Was sensor removed for testing? <br />❑ Yes ❑ No N NA <br />❑ Yes ❑ No N NA <br />❑ Yes ❑ No N NA <br />p Yes ❑ No N NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />❑ Yes ❑ No N NA <br />❑ Yes ❑ No N NA <br />❑ Yes ❑ No N NA <br />❑ Yes ❑ No N NA <br />Comments - (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />