My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008-2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3202
>
2300 - Underground Storage Tank Program
>
PR0231129
>
COMPLIANCE INFO_2008-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/29/2021 4:28:20 PM
Creation date
6/3/2020 9:45:08 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2011
RECORD_ID
PR0231129
PE
2361
FACILITY_ID
FA0001817
FACILITY_NAME
7-ELEVEN INC #35355
STREET_NUMBER
3202
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
Ln
City
Stockton
Zip
95209
CURRENT_STATUS
01
SITE_LOCATION
3202 W Hammer Ln
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231129_3202 W HAMMER_2008-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
362
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page_4_of—7- <br /> 6. PIPING SUMP TESTING <br /> Test Method Developed By: ❑ Sump Manufacturer ® Industry Standard ❑Professional Engineer <br /> ❑ Other(Spec) <br /> Test Method Used: ❑ Pressure ❑ Vacuum ® Hydrostatic <br /> ❑ Other(Spec) <br /> Test Equipment Used: INCON SUMP TESTER Equipment Resolution: +/-0.002" <br /> Sump#87 Sump#91 Sump#DIESEL Sump# <br /> Sump Diameter: 48" 48" 48" <br /> Sump Depth: 59.50" 59.00" 60.00" <br /> Sump Material: FIBERGLASS FIBERGLASS FIBERGLASS <br /> Height from Tank Top to Top of 11.50" 9.50" 9.50" <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 9.50" 9.00" 10.00" <br /> Electrical Penetration: <br /> Condition of sump prior to testing: DRY DRY DRY <br /> Portion of Sump Tested' ABOVE ABOVE ABOVE <br /> PENETRATION PENETRATION PENETRATION <br /> Does turbine shut down when <br /> sump sensor detects liquid(both ®Yes ❑No ❑NA ®Yes []No ❑NA ®Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> product and water)?' <br /> Turbine shutdown response time 3 SEC 3 SEC 3 SEC <br /> Is system programmed for fail-safe ®Yes ❑No [-INA ®Yes ❑No ❑NA ®Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> shutdown?* <br /> Was fail-safe verified to be <br /> operational?* <br /> fail-safe <br /> ®Yes ❑No ❑NA ®Yes ❑No ❑NA ®Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> Wait time between applying <br /> pressure/vacuum/water and starting 10 MIN 10 MIN 10 MIN <br /> test: <br /> Test Start Time: 9:15 AM 9:15 AM 9:15 AM <br /> Initial Reading(RI): 5.5058" 6.0560" 4.3081" <br /> Test End Time: 9:30 AM 9:30 AM 9:30 AM <br /> Final Reading(RF): 5.5057' 6.0560" 4.3078" <br /> Test Duration: 15 MIN 15 MIN 15 MIN <br /> Change in Reading(RF-RI): -0.0001" 0.000" -0.0003" <br /> Pass/Fail Threshold or Criteria: +/-0.002" +/-0.002" +/-0.002" +/-0.002" <br /> Test Result: Z Pass ❑Fail Z Pass ❑Fail Z Pass ❑Fail []Q Pass ❑Fail <br /> Was sensor removed for testing? ®Yes ❑No ❑NA ®Yes ❑No ❑NA ®Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> Was sensor properly replaced and <br /> verified functional after testin ? ®Yes [:]No ❑NA ®Yes ❑No [:1 NA ®Yes [I No [__1 NA ❑Yes [:]No ❑NA <br /> Comments— (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> ABOVE IS THE LAST OF TWO BACK TO BACK 15 MINUTE TESTS <br /> 1 If the entire depth of the sump is not tested,specify how much was tested. If the answer to qny of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire sump must be tested. (See SWRCB LG-160) <br />