My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008-2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3202
>
2300 - Underground Storage Tank Program
>
PR0231129
>
COMPLIANCE INFO_2008-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/29/2021 4:28:20 PM
Creation date
6/3/2020 9:45:08 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2011
RECORD_ID
PR0231129
PE
2361
FACILITY_ID
FA0001817
FACILITY_NAME
7-ELEVEN INC #35355
STREET_NUMBER
3202
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
Ln
City
Stockton
Zip
95209
CURRENT_STATUS
01
SITE_LOCATION
3202 W Hammer Ln
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231129_3202 W HAMMER_2008-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
362
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB, January 2006 <br />This form is intended for use by contractors performing annual testing of UST spill containment structures. The completed form and <br />printouts from tests (f applicable) should be provided to the facility owner/operator for submittal to the local regulatory agency. <br />1. FACILITY INFORMATION <br />Facility Name: CRLLC #2705448 1 Date of Testing: FEB 19, 2010 <br />Facility Address: 3202 W. HAMMER LANE, STOCKTON, CA 95209 <br />Facility Contact: ARMEN MKRTYTCHIAN I Phone: (925) 884-0800 <br />Date Local Agency Was Notified of Testing: FEB 8, 2010 <br />Name of Local Agency Inspector (zf present during testing): GARRETT BACKUS <br />2. TESTING CONTRACTOR INFORMATION <br />Company Name: TANK-TEK ENVIRONMENTAL CORPORATION <br />Technician Conducting Test: RICHARD THOMAS <br />Credentials': ® CSLB Contractor ® ICC Service Tech. ® SWRCB Tank Tester ❑ Other (Spec) <br />License Number(s): 803705 (CSLB Contractor) -- 5254736 -UT (ICC Service Tech.) -- 06-1672 (SWRCB Tank Tester) <br />3. SPILL BUCKET TESTING INFORMATION <br />Test Method Used: ® Hydrostatic ❑ Vacuum ❑ Other (Spec) <br />Test Equipment Used: VISUAL <br />Equipment Resolution: <br />. <br />..,,.u. .. 77,77777-1 <br />Identify Spill Bucket (By Tank <br />Number, Stored Product, etc.) <br />87 FILL <br />91 FILL <br />DIESEL FILL <br />Bucket Installation Type: <br />® Direct Bury <br />❑ Contained in Sump <br />® Direct Bury <br />❑ Contained in Sump <br />® Direct Bury <br />❑ Contained in Sump <br />❑ Direct Bury <br />❑ Contained in Sump <br />Bucket Diameter: <br />14.00" <br />14.00" <br />14.00" <br />Bucket Depth: <br />14.25" <br />15.50" <br />13.75" <br />Wait time between applying <br />vacuum/water and start of test: <br />10 MIN <br />10 MIN <br />10 MIN <br />Test Start Time (TI): <br />8:30 AM <br />8:30 AM <br />8:30 AM <br />Initial Reading (RI): <br />14.25" <br />15.50" <br />13.75" <br />Test End Time (TF): <br />9:30 AM <br />9:30 AM <br />9:30 AM <br />Final Reading (RF): <br />14.25" <br />15.50" <br />13.75" <br />Test Duration (TF — TI): <br />1 HR <br />1 HR <br />1 HR <br />Change in Reading (RF - RI): <br />0 <br />0 <br />0 <br />Pass/Fail Threshold or Criteria: <br />Test Result: <br />Z Pass ❑ Fail <br />Z Pass ❑ Fail <br />Z Pass ❑ Fail <br />❑ Pass ❑ Fail <br />Comments - (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING <br />I hereby certify that all the Information contained in this report is true, accurate, and in full compliance with legal requirements. <br />Technician's Signature: <br />Date: FEB 19, 2010 <br />' State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements <br />may be more stringent. <br />
The URL can be used to link to this page
Your browser does not support the video tag.