My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008-2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3202
>
2300 - Underground Storage Tank Program
>
PR0231129
>
COMPLIANCE INFO_2008-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/29/2021 4:28:20 PM
Creation date
6/3/2020 9:45:08 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2011
RECORD_ID
PR0231129
PE
2361
FACILITY_ID
FA0001817
FACILITY_NAME
7-ELEVEN INC #35355
STREET_NUMBER
3202
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
Ln
City
Stockton
Zip
95209
CURRENT_STATUS
01
SITE_LOCATION
3202 W Hammer Ln
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231129_3202 W HAMMER_2008-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
362
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
V M <br /> UNIFIED PROGRAM CONSOLIDATED FO <br /> UNDERGROUNDSTORAGETANK <br /> MONITORING PLAN-jPagt 1 of 2 <br /> TYPE OF ACTION ❑ ].NEW PLAN 2.CHANGE OF INFORMATION 490.1. <br /> PLAN TYPE 1,MONITORING IS IDENTICAL FOR ALL USTs AT MS FACILITY, 490.4. <br /> (Cheek one item only) ❑ 2.THIS PLAN COVERS ONLY THE FOLLOWING UST SYSTEM(S): <br /> FACILITY ID#(Agency Use Only) <br /> tt_ <br /> BUSINFSS NAME as Facility Name or DBA) 3. <br /> CRLLC#5448 <br /> BUSINESS SITE ADDRESS 103- CTTY 104. <br /> 3202 W.Hammer Ln. Stockton <br /> j .. . w. <br /> Testing,preventive maintenance, calibration of monitoring equipment(c g sensors,probes,line 1 detectars }must be perlormed at the feeque s ified <br /> ihe_egu�PT"_manufacturers mstructicrns or annually,whichcyer is more fregi nt Such work must be perfomved by quattTied rsonnel Iz3 cca gze3z enc 2s39.264 11 <br /> MONITORING EQUIPMENT IS SERVICED L A UALLY ❑ 99,OTHER(Specify): 490.3& <br /> ,. .. 490.3k <br /> ❑ t.NEW SITE PLOT PLAN/MAP SUBMITTED WITH THIS PLAN4904 <br /> 2.SITE PLOT PLAN/MAP PREVIOUSLY SUBMITTED 123 CCR gz63a,66361 <br /> + 4 <br /> L CONTINUOUS ELE ONIC TANK MONI RING QF ANNULAR(INTERSTITIAL)SPACE(S)OR SECONDARY CONTAINMENT VAULTS) s. <br /> WITH AUDIBLE AND VISUAL ALARMS.(23 CCR 1x632,26341 <br /> SECONDARY CONTAINMENT IS: 0 a.DRY 0 b.LIQUID FILLED 0 c.PRESSURIZED ❑ d.UNDER VACUUM 4 <br /> PANEL MANUFACTURER: Veeder Root 490.9. MODEL#: TLS-350 WISD alas. <br /> LEAK SENSOR MANUFACTURER: Veeder❑ R 9. MODEL#(S): 407J 490-90. <br /> 2.AUTOMATIC TANK GAUGING(ATG)SYSTEM USESW , 63 <br /> CCR g26431 <br /> PANEL MANUFACTURER: 490-11 MODEL#: 49043 <br /> 1N-TANK PROBE MANUFACTURER: 49044 MODEL#(S): 4WIi <br /> LEAK TEST FREQUENCY: ❑ a.CONTINUOUS <br /> ❑ b.DAILY/NIGHTLY ❑ c.WEEKLY 4 .t6. <br /> ❑ d.MONTHLY ❑ e,OTHER(Specify): a IT <br /> PROGRAMMED TESTS: 690 Ia. <br /> _ _. - -❑ a,a. P h ___ Q �ti 4 2 a_h.. . _D e.OT (scify) <br /> ❑ 3 MONTH LY STATISTICAL INVENTORY RECONCILIATION l23 CCR g tl _ a X9.20_ <br /> _ ____ ._._. _. _._..__ _ <br /> ❑ <br /> -4-.--,WE-EMANUA <br /> KLY L TANK GAUGI (MTG)l[UccR gz6asl TESTING PERIOD: ❑ a.36 HOURS__ ❑.. __ <br /> b.64 HOURS 4 - <br /> _._ <br /> ❑ S.TANK[ GRITY TESTING PER 123 CCR 16643.11 _.._... 4 -23. <br /> REQUENCY: - ❑ a.ANNUALLY b.BIENNIALLY a9aaa. <br /> ❑ 49,OTHER .S._.. _.... ... e.OTHER(S 3eoify): <br /> TF <br /> zs: <br /> ( Ci ): 490-26. <br /> 490.27 <br /> " ` ' I <br /> tttt <br /> 1.CONTINUOUS MONITORING OF PIP IPING SUMP(S)AND OTHERSECONDARY CONTAINMENTWITH AUDIBLE&VISUAL ALARMS. 4 as <br /> [23 CCR <br /> 12633 <br /> SECONDARY CONTAINMENT IS: a.DRY <br /> ® b.LIQUID FILLED ❑ e.PRESSURIZED ❑ d.UNDER VACUUM 490,29. <br /> PANEL MANUFACTURER: Veeder Rout 49a3o. <br /> MODEL#: TLS- wflSD 631. <br /> LEAK SENSOR MANUFACTURER: V 49036. MODEL#(S): 208 490.33. <br /> PIPING LEAK ALARM TRIGGERS AUTOMATIC PUMP(i.e.,TU INE)SH a YES ❑ b.NO 490-34. <br /> FAILURE/DISCONNECTION OF THE MONITORING SYSTEM _IGGERS AUTOMATIC PUMP SHUTDOWN. a YES b.NO 490.31. <br /> IN 2.MECHANICAL LINE Lh .®..__ - 4(MLL5)THAT ROUTINELYµPERFORM5 3.4 .____- ______. ._.___ _ <br /> g.p.h.LEAK TESTS AND RESTRICTS OR SHUTS OFF e90is. <br /> PRODUCT FLOW WHEN A LEAK IS DETECTED.la3 cCRg26361 <br /> MLLD MANUFACTURER(S): FE Petro!VMI 490-37, MODEL#(S): STP-MLD and 99LD2000 438, <br /> 3.ELECTRONIC LINE LEAK DETECTOR(ELLD)THAT ROUTINELY PERFORMS 3.0g.p.h.LEAKTESTSncCR <br /> 49039, <br /> ELLD MANUFACTURER(S): 490-40 Ig26361 ._. <br /> MODEL#(S): 49"I. <br /> PROGRAMMED IN LINE LEAK TEST: ❑ a.MINIMUM MONTHLY0.2 g.p.h. ❑ b.MINIMUM ANNUAL 0.1h. 49041 <br /> ELLD DETECTION OF A PIPING LEAK TRIGGERS AUTOMATIC PUMP SH ❑ a.YES b.NO <br /> g P 490-41 <br /> Q <br /> ELLD FAILU ISCO ON TRIGGERS AUTOMATIC PUMP SH ® ❑ b.No 490.44, <br /> a.YES <br /> __... <br /> 4.PIPE INTEGRITY TES G. <br /> 490-45. <br /> TEST FREQUENCY: a ANNUALLY b.EVERY 3 YEARS ❑ c.OTHER(S tfy) 490-46, <br /> ❑ S.VISUAL PIPE MONITORING. _.__ <br /> FREQUENCY: Ela.DAILY a .B <br /> b.WEEKLY C.MIN.MONTHLY&EACH TIME SYSTEM OPERATED* 49049 <br /> ❑ 6 SUCTION PIPING MEL"i S EXEMPTION CRITERIA.lz3 CCR ga636t.S3>I 490-so. <br /> ?NO REGULATED PIPING PER HEALTH AND SAFETY CODE,DIVISION 24,CHAPTER 6.7 IS CONNECTED TO THE TANK SYSTEM. a90.si: <br /> �._ <br /> .OTHER(Si <br /> 49o:sz. <br /> 69013. <br /> UPC'F UST-D(12/2007)-1J4 www.unidoes.org <br />
The URL can be used to link to this page
Your browser does not support the video tag.