My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008-2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3202
>
2300 - Underground Storage Tank Program
>
PR0231129
>
COMPLIANCE INFO_2008-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/29/2021 4:28:20 PM
Creation date
6/3/2020 9:45:08 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2011
RECORD_ID
PR0231129
PE
2361
FACILITY_ID
FA0001817
FACILITY_NAME
7-ELEVEN INC #35355
STREET_NUMBER
3202
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
Ln
City
Stockton
Zip
95209
CURRENT_STATUS
01
SITE_LOCATION
3202 W Hammer Ln
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231129_3202 W HAMMER_2008-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
362
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
} <br /> UNIFIED PROGRAM CONSOLIDATED FORM WIN <br /> UNDERGROUND STORAGE TANK <br /> NIT —(Page 2of2 <br /> ORION In <br /> UDC MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S) " <br /> ❑ L CONTINUOUS ELECTRONIC MONITORING ® 2.FLOAT AND CHAIN ASSEMBLY ❑ 3.ELECTRONIC STAND-ALONE 49 sea <br /> ❑ 4.NO DISPENSERS ❑ 49 OTHER(Specify) 490-54b. <br /> LEAK MONITOR MANUFACTURER: a s MODEL#: 96:5(C <br /> LEAK SENSOR MANUFACTURER: 490-57 MODEL#(S): 490-58, <br /> DETECTION OF A LEAK INTO THE UDC TRIGGERS AUDIBLE AND VISUAL ALARMS. ❑ a YES b.NO 490-19. <br /> UDC LEAK ALARM TRIGGERS AUTOMATIC PUMP SHUTDOWN, ❑ a.YES b.NO <br /> FAILURE/DISCONNECTION OF UDC MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑ a.YES IN b.NO 490.61. <br /> UDC MONITORING STOPS THE FLOW OF PRODUCT AT THE DISPENSER. 490-62 <br /> _.,. _ _ a.YES ❑ b NO <br /> UDC CONSTRUCTION IS: ._...___- <br /> I.SINGLE WALL --4"-6_____...._. <br /> 2.DOUBLE WALL a�-si. <br /> IF UBLE WAI : <br /> ago-ea. <br /> UDC INTERSTITIAL SPACE IS MONITORED BY: ❑ a LIQUID ❑ b.PRESSURE ❑ c.VACUUM <br /> A LEAK WITHIN THE SECONDARY CONT,A,INM,ENT,OF THE UDC TRIGGERS AUDIBLE AND VISUAL ALARMS. ❑ a.YES ❑ b.NO 490-64b. <br /> I.ELD TESTING. IS FACILITY HAS BEEN NOTIFIED BY STATE WATER RESOURCES CONTROL BOA THAT ENHANCFn 490'-65. <br /> MUST BE PERFORMED. PERIODIC ELI)IS PERFORMED EVERY 36 MONTHS AS REQUIRED. as Cca ta6aa.t <br /> 2.SECONDARY CONTAINM T COMI�INENTS ARE TESTED EVERY 36 MONTHS. a <br /> 3.SPILL BUC ARE TESTED A UALLY. <br /> 49047 <br /> .. ' <br /> The followi �r''i n, <br /> g/mainteriance records am kept for this thcntty: a '`a <br /> a.ALARM LOGS ® b.VISUAL INSPECTION RECORDS ❑ c.TANK INTEGRITY TESTING RESULTS <br /> ❑ d.SIR TESTING RESULTS(and supporting documentation records) ❑ e.TANK GAUGING RESULTS(and supporting documentation records) <br /> f ATG TESTING RESULTS(and supporting documentation records) ❑ g.CORROSION PROTECTION DAY LOGS <br /> h.E )UIPMENT MAINTENANCE AND CALIBRATION RECORDS <br /> Personnel with UST monitoring ibitities f iliac with all of the fallowing" uments relevant m ttreir job <br /> REFERENCEduties: .4 v <br /> DOCUMENTS [NTAINED AT FACILITY(Check ati Iliac DIY) <br /> THIS UNDERGROUND STORAGE TANK MONITORING FLAN(Rsqui } <br /> OPERATING MANUALS FOR ELE ONIC MONITORING EQUIPMENT(Required} <br /> [3CALIFORNIA UNDERGROUND STORAGE TANK GULATIONS 490-0c. <br /> [3CALIFORNIA UNDERGROUND STORAGE TANK LAW a <br /> STATE WATER RESOURCES CONTROL A a <br /> (S CB) PUBLICATION: "HANDBOOK FOR 'TANK OWNERS - MANUAL AND a <br /> STATISTICAL INVENTORYRECONCILIATION" <br /> ❑SWRCB PUBLICATION:"UNDERSTANDING AUTOMATIC TANK GAUGING SYSTEMS" 490-698. <br /> ❑ OTHER(Specify): <br /> 490-6%. <br /> 11119 This facility has a"Designated UST Operator"who California UST Sy m rator E administered: the 1111tonal Code Council a <br /> azo. <br /> (ICC). The "Designated UST Operator"will train facility employees in the proper operation and maintenance of the UST systems annually,and within 30 <br /> days of l ire.This training will include,but is not limited to,the following: <br /> > Operation of the UST systems in a manner consistent with the facility's best management practices. <br /> ➢ The facility employee's role with regard to the monitoring equipment as specified in this UST Monitoring Plan. <br /> D The facility employee's role with regard to spills and overfills as specified in the facility's UST Response Plan. <br /> > Name(s)of contact person(s)for emergencies and monitoring al <br /> vide additional commentsre or itxli to how pages with iii info ton ons iftc mani Ing procedures a to this plan. <br /> Gu ntly the alta Itaa over till ntlon of rrtechanit�l flap aet et 9596 of tank cepaclty. 490.71. <br /> The UST r! calor is responsible for utittg that: L}the daily! tine UST mall ietg putties maintenance"of UST leak detection equipment covered <br /> b tftis oceursR 2.�plt cotutition that Indic assible-I---are investi and 3j all monitorm records are maintained to rl . <br /> THE FOLLOWING PERSONS)ARE RESPONSIBLE FOR PERFORMING THE MONITORING AND EQUIPMENT MAINTENANCE <br /> NAME: Affen Fam 490.72. TITLE: <br /> NAME: an 490-73. <br /> 490'-74 TITLE: 49e.75. <br /> i ed UST r shaft1 riforim a monthly visual inspection of the facility,provide a report to the o rloperator,and inform the owner/operator of any <br /> conditions that follow-u action. <br /> `- <br /> OR SIGNATURE , <br /> #AIPIeLn'CFaass <br /> ON;[cern that the Into atioa rovlded herein is true and accurate to the best of m knowledge. <br /> ADATE: <br /> j�l Tm er er a9¢-76, 1`11- <br /> E(print}: 496-78. APPLICANTTITLE: 490.79. <br /> Complian <br /> ce <br /> UPCFUST-A(IV2 )-3!4 w.unidecs.org <br />