Laserfiche WebLink
• Before placing sump on tank fitting adapters, place <br /> approved backfill between the tank top and sump <br /> bottom. Ensure there will be no backfill voids under The use of approved backfill material is critical <br /> the sump. to long term sump performance. Failure to use <br /> Figure E-2 approved backfill may result in sump failure. <br /> Proper Backfill Installation Improper Backfill Installation • Replace all excavated native soil with approved <br /> backfill of proper sized and gradation. Use backfill <br /> Sump Backfin ° sump Backfill which meets ASTM C-33 for quality and soundness. <br /> • Require your backfill supplier to certify that the backfill <br /> uo meets this specification. <br /> • Keep backfill dry and free of ice in freezing conditions. <br /> • Use only the following approved backfills. <br /> •o •n Air Void Figure G-1 <br /> 7 Right wrong PEA GRAVEL CRUSHED STONE <br /> Tank Fitting Tank Fitting <br /> • Position sump on tank fitting adapters, continue to <br /> place backfill under the sump bottom. <br /> (73/4" 1/2" <br /> • Complete fitting manufacturers installation of tank m) (12 mm) <br /> fitting adapters. <br /> • Before standing in sump or seating lid, place Maximum Size <br /> approved backfill between the tank top and sump Maximum Size <br /> bottom. Ensure there will be no backfill voids under <br /> the sump. 1" <br /> • Complete installation of sump per the installation 3/4r <br /> instructions. <br /> 1 �� <br /> • Keep the sump lid, o-ring and o-ring groove free from 2 <br /> contaminates. 1/4r _ <br /> • When installing lid, apply additional lubricant as <br /> needed. E2,_ <br /> • Step on lid perimeter until lid pops into place and is Pea Gravel: Crushed Stone or Gravel: <br /> properly seated. Clean naturally-rounded Washed,with angular <br /> aggregate with particle particle sizes no larger <br /> INIMMY-11"Im! e • sizes no larger than%" than%"with no more <br /> with no more than 5% than 5%passing a <br /> passing a#8 sieve. #8 sieve. <br /> Dry density must be a Dry density must be a <br /> DO NOT pressure test sump or DO NOT apply more than minimum of 95 pounds minimum of 95 pounds <br /> 25 inches water vacuum to sump enclosure or damage per cubic foot. per cubic foot. <br /> may occur. <br /> Note: If material which meets these specifications <br /> • Fill sump with water at least 3"above highest joint or is not available, contact the Containment Solutions <br /> penetration. Technical Support department for information <br /> • Record the liquid level. on approved alternate materials and installation <br /> instructions. Using other than approved bedding and <br /> • Wait 24 hours. backfill materials without Containment Solutions's <br /> • Re-measure and record the liquid level.A liquid prior written approval will void the sump warranty <br /> change of more than W indicates a possible leak. and may result in sump failure. <br /> • As an alternative, 25 inches water vacuum may ALTERNATE BACKFILL FOR SUMPS -SAND <br /> be applied to the sump. CSI Sump Vacuum Test If the tank is installed in pea gravel, crushed stone, <br /> Procedure for O-ring Top must be followed. The WTL or other porous backfill, a continuous layer of CSI <br /> testable lid must be ordered to perform this test. approved geotextile fabric must be installed at the <br /> tank top prior to backfilling sumps with sand. Refer <br /> to INST 6001 for specific requirements on geotextile. <br /> 5 <br />