COMPLIANCE INFO_2010-2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAZELTON
>
1810
>
2300 - Underground Storage Tank Program
>
PR0231141
>
COMPLIANCE INFO_2010-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2024 3:15:12 PM
Creation date
6/3/2020 9:45:26 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2012
RECORD_ID
PR0231141
PE
2361
FACILITY_ID
FA0003954
FACILITY_NAME
SJ CO PUBLIC WORKS CORP YARD*
STREET_NUMBER
1810
Direction
E
STREET_NAME
HAZELTON
STREET_TYPE
AVE
City
STOCKTON
Zip
95205
APN
15518002
CURRENT_STATUS
01
SITE_LOCATION
1810 E HAZELTON AVE
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231141_1810 E HAZELTON_2010-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
264
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br /> 4kNVIRONMENTAL HEALTH DEPARTMENT • <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.siaov.org/ehd/unitiii.html <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT CONTINUED <br /> Facility <br /> Name: SJC Public Works Corp. Yard Address: 1810 E. Hazelton, Stockton Dateection Mar 9, 2012 <br /> VIOLATIONS <br /> # C1 C2 M I Code Section HSC=CA Health and Safety Code;CFR=Code of Federal Regulations <br /> C1=Class 1 violation;C2=Class 2 violation;M=Minor violation <br /> Non-Pressurized Piping(continued) <br /> 702 1 CCR 2643(e) Biennial tightness test of gravity piping not performed(pre-January 1,1984) (M1) <br /> 703 1 CCR 2643(d) Triennial line test for conventional suction piping not performed(pre-January 1, 1984) (M7) <br /> Other Violations <br /> 999 Other: See attached"Continuation—Official Inspection Report"for violation(s)not listed above. <br /> SUMMARY OF VIOLATIONS <br /> CLASS CLASS II r MINOR-Notice to Comply) <br /> This is a Routine and Monitoring Certification inspection. The following is a Minor- Notice to Comply: <br /> #203, and the following are Class II Repeat violations: 104, 106,202, 302/308, 311 <br /> 104. Financial responsibility documents have not been submitted to the EHD. Current financial <br /> responsibility documents are required to be submitted annually. A copy of the financial responsibility <br /> documents dated January 10, 2012 were received on site. <br /> 106. The response plan on site are not current and not approved by the EHD. The monitoring and <br /> response plans must be current and approved by the EHD. A current copy of the completed response <br /> plan was received on site by EHD, and has been approved by the EHD. <br /> 202. Approved copies of the monitoring plan was not found on site. Copies of these plans shall be <br /> retained on site at all times. This violation was corrected on site. <br /> 203. Approximately quarter cup of diesel in the middle diesel UDC pan was observed during this <br /> inspection and it was not recorded. Any release from the primary containment that does not escape the <br /> secondary containment and was cleaned up within eight hours of being detected shall be recorded with <br /> the following information: <br /> 1. Operators name and phone number <br /> 2. List of types, quantities, and concentrations of hazardous substances released <br /> 3. Description of actions taken to control and clean the release <br /> 4. Method and location of disposal of the released substances <br /> 5. Description of actions taken to repair and prevent future releases <br /> 6. Description of method used to reactivate interstitial monitoring after repair or replacement of <br /> primary containment <br /> Immediately clean up the above spill and properly dispose of the waste properly, and record this release <br /> with the information required, and maintain it on site with the facility's monitoring records. Submit a copy <br /> of the recordable release statement to the EHD by Apirl 9, 2012. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUB ECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Inspector. eceiv By. Title: <br /> EH 02 Rev 0 1 Page 3 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.