Laserfiche WebLink
HL <br />GROUP INC. <br />JOHN W.JOHNSON <br />A rchitect <br />Co -President <br />ARCHITECTURE • ENGINEERING • ENVIRONMENTAL SERVICES <br />1137 North McDowell Blvd., Petaluma, CA 94954-1110 Telephone: (707) 765-1660 Facsimile: (707) 765-9908 <br />March 22, 1999 <br />Mr. Michael Kith, Sr. REHS <br />BRIAN F. ZITA San Joaquin County <br />Architect Public Health Services <br />Co -President Environmental Health Division <br />304 East Weber Avenue, Third Floor <br />Stockton, CA 95202 <br />JOHN B. HICKS <br />Architect RE: RICK'S CHEVRON <br />Vice President 8600 LOWER SACRAMENTO ROAD <br />STOCKTON,CA <br />RHL JOB No. 9668.30 <br />r' -,— R SPENCER <br />E s t a b l i s h e d 1 9 6 6 <br />Architect The following is in response to your plan check comments dated March 3, 1999. <br />Vice President <br />tel. Contractor's Information <br />Contractor information has been added to the application. See attached application. <br />ALAN SHIMABUKUR <br />2. Board of Equalization number <br />Regional Manager <br />Associate Pending. Application for BOE # has been filed. <br />--,-,3. Question 1-11 on page 5 and question 16a -c on page 7 of the application. <br />Items #1 through #11 and #16 have been completed. See attached application. <br />CHRIS L A W T QN <br />Regional Manage <br />Associate 4. <br />JAMES E. PREST <br />Regional Manager <br />Associate 5. <br />Plan is not site-specific. Page F2 and F3 of the plan show several tank and piping <br />layouts. Provide site-specific plan, piping layout, cross-sectional diagram of the tank <br />and list of equipment. <br />Plans have been made site-specific. <br />Application indicates 3 tanks to be installed; the plan indicates 5 tanks, a l OK, two 12K, <br />a 15K and a 1K used oil tank to be installed. Please provide an accurate number of <br />tanks to be installed. Submit additional form B as needed. <br />Plans have been made site-specific. <br />GARY M. SE MLI G <br />Managing Architect 6. F 1 of the plan indicates the piping are A-0 Smith and Evironflex. Please specify and <br />Associate <br />submit cut -sheet as needed. <br />Plans have been made site-specific. <br />BLYTHE R. WILSON 7. Pressure line leak detector FE Petro #VR 848480-001 and interstitial sensor 794390 - <br />Managing Architect 409 as indicated on FI of the plan are not on LG 113-12. Please specify and submit <br />Associate cut -sheet for the line leak detector and sensor to be installed. <br />Pressure line leak detector is Feeder Root #848480-001. Intersitial sensor made for <br />8'0" tanks is Feeder Root #794390-407. See Sheet F1. <br />B E L L E V U E, WA LA H A B R A, CA SACRAMENTO, CA S C O T T S D A L E, Az <br />