My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2002-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOWER SACRAMENTO
>
8660
>
2300 - Underground Storage Tank Program
>
PR0231161
>
COMPLIANCE INFO_2002-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/13/2023 2:51:09 PM
Creation date
6/3/2020 9:45:40 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002-2015
RECORD_ID
PR0231161
PE
2361
FACILITY_ID
FA0003726
FACILITY_NAME
fast and easy mart #103
STREET_NUMBER
8660
STREET_NAME
LOWER SACRAMENTO
STREET_TYPE
RD
City
STOCKTON
Zip
95210
APN
079-170-390-000
CURRENT_STATUS
01
SITE_LOCATION
8660 LOWER SACRAMENTO RD
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231161_8660 LOWER SACRAMENTO_2002-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
484
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mar 02 09 07:22a <br />SWRCB, January 2002 <br />JP Petroleum Service <br />916372 73 <br />P.3 <br />Page of <br />4. TANK ANNULAR TESTING <br />Test Method Developed By: x Tank Manufacturer ❑ Industry Standard 0 Professional Engineer <br />O Other (Spec6) <br />Test Method Used: 0 Pressure x Vacuum 0 Hydrostatic <br />❑ Other (Spec) <br />Test Equipment Used: Dwyer Manometer Equipment Resolution: +/- 2% <br />Tank # 1 <br />Tank # 2 <br />Tank # 3 <br />Tank # <br />Is Tank Exempt From Testing?' O Yes x No <br />❑ Yes x No <br />D Yes x No <br />❑ Yes O No <br />Tank Capacity: 10,000 <br />10,000 <br />10,000 <br />Tank Material: Fiberglass <br />Fiberglass <br />Fiberglass <br />Tank Manufacturer. Xeres <br />Xeres <br />Xeres <br />Product Stored: Regular <br />Plus <br />Premium <br />Wait time between applying <br />pressure/vacuum/water and 30 min <br />starting test: <br />30 min <br />30 min <br />30 rain <br />Test Start Time: 11:15 <br />9:55 <br />9:05 <br />Initial Reading (R,): 7.98 <br />8.19 <br />7.84 <br />Test End Time: 12:15 <br />10:55 <br />10:05 <br />Final Reading (RF): 7.14 <br />7.27 <br />7.16 <br />Test Duration: I hour <br />I hour <br />1 hour <br />I hour <br />Change in Reading (RF -R,): .84 <br />.92 <br />.68 <br />Pass/Fail Threshold or Criteria: No less than I" <br />No less than 1" <br />No less than I" <br />No less than I" <br />Test Result: X Pass ❑ Fail <br />x Pass 0 Fail <br />x Pass ❑ Fail <br />0 Pass 0 Fail <br />Was sensor removed for testing? x Yes 0 No ❑ NA <br />x Yes O No D NA <br />x Yes ❑ No DNA <br />x Yes ❑ No 0 NA <br />Was sensor properly replaced and x Yes 0 No 0 NA <br />verified functional after testing! <br />x Yes ❑ No 0 NA <br />x Yes 0 No DNA <br />x Yes ❑ No 0 NA <br />Comments —(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />r Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br />containment, such as systems that are hydrostatically monitored or under constant vacuum, are exempt from periodic containment <br />toct," frAlifnrnia r-Ao TitIP 11 Cortin- ?F.27fa1lf+li <br />
The URL can be used to link to this page
Your browser does not support the video tag.