SVirRCB, January 2002 7. 1KRERRISPE11RE �,AT4,AKW&VT if DOC) TIPST-WG Page of <br />Test Method Developed By: 0 UDC Manufacturer El Industry Standard X Professional Engineer <br />0 Other (Specify) <br />Test Method Used: 0 Pressure 0 Vacuum X Hydrostatic <br />11 Other (Specify) <br />Test Equipment Used: Caldwell Systems <br />Equipment Resolution: .005/30 min <br />UDC # 1&2 <br />UDC #3&4 <br />UDC # 5&6 <br />UDC #7&8 <br />UDC Manufacturer: <br />Western <br />Western <br />Western <br />Western <br />UDC Material: <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />UDC Depth: <br />24" <br />24" <br />24" <br />24" <br />Height from UDC Bottom to Top <br />11" <br />11" <br />1013 <br />1015 <br />of Highest Piping Penetration: <br />Height from UDC Bottom to <br />711 <br />7" <br />71' <br />791 <br />Lowest Electrical Penetration: <br />Condition of UDC prior to <br />Dry <br />Dry <br />Dry <br />Dry <br />testing: <br />Portion of UDC Tested <br />2" above <br />Highest <br />Piping <br />penetration <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />xYes ONo DNA <br />xYes DNoONA <br />x Yes 0 No DNA <br />x Yes 0 No D NA <br />product and water)?* <br />Turbine shutdown response time <br />Is system programmed for fail- <br />safe shutdown?* <br />xYes ONo DNA <br />xYes 0No0NA <br />x Yes 0 No DNA <br />x Yes 0 No DNA <br />Was fail-safe verified to be <br />ope ional?* <br />0 Yes xNo DNA <br />OYes xNo DNA <br />0 Yes xNo DNA <br />0 Yes x No DNA <br />Wait time between applying <br />pressure/vacuum/water and <br />5 min <br />5 min <br />5 min <br />5 min <br />starting test <br />Test Start Time: <br />12:20 <br />12:30 <br />12:10 <br />10:40 <br />Initial Reading (RI): <br />.001, <br />.00" <br />.001, <br />.001, <br />Test End Time: <br />12:50 <br />1:00 <br />12:40 <br />11:10 <br />Final Reading (RF):- <br />.00 <br />.00 <br />.00 <br />.0025 <br />Test Duration: <br />30 min <br />30 min <br />30 min <br />30 min <br />Change in Reading (RF-Rj: <br />.00 <br />.00 <br />.00 <br />.0025 <br />Pass/Fail Threshold or Criteria: <br />.005/30 min <br />.005/30 min <br />.005/30 min <br />.005/30 mi <br />Test Result: <br />x Pass 0 Fail <br />x Pass 0 Fail <br />x Pass 0 Fail <br />x Pass 0 Fail <br />m <br />Was sensor removed for testing? <br />xYes ONo DNA <br />xYes ONoONA <br />x Yes 0 No 0 NA <br />x Yes 0 No 0 NA <br />Was sensor properly replaced and <br />t2verified functional after tes rn ? <br />x Yes 0 No 0 NA <br />x Yes 0 No 0 NA <br />x Yes 0 No 0 NA <br />x Yes 0 No 0 NA <br />Comments — include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />1 If the entire depth of the UDC is not tested, specify how much was tested. If the answer to an of the questions indicated with an <br />asterisk (*) is "NO" or "NX', the entire UDC must be tested. (See SWRCB LG -160) <br />