My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2002-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOWER SACRAMENTO
>
8660
>
2300 - Underground Storage Tank Program
>
PR0231161
>
COMPLIANCE INFO_2002-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/13/2023 2:51:09 PM
Creation date
6/3/2020 9:45:40 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002-2015
RECORD_ID
PR0231161
PE
2361
FACILITY_ID
FA0003726
FACILITY_NAME
fast and easy mart #103
STREET_NUMBER
8660
STREET_NAME
LOWER SACRAMENTO
STREET_TYPE
RD
City
STOCKTON
Zip
95210
APN
079-170-390-000
CURRENT_STATUS
01
SITE_LOCATION
8660 LOWER SACRAMENTO RD
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231161_8660 LOWER SACRAMENTO_2002-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
484
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB, January 2002 6. PEPING SUMEP TESTING <br />Page of <br />Test Method Developed By: El Sump Manufacturer 0 Industry Standard X Professional Engineer <br />0 Other (Specify) <br />Test Method Used: 0 Pressure 0 Vacuum X Hydrostatic <br />0 Other (Sped) <br />Test Equipment Used: Caldwell Systems <br />Equipment Resolution: .005/30 min <br />I <br />Sump # 2 <br />Sump # 3 <br />Sump # <br />Sump Diameter: <br />42" <br />42" <br />4211 <br />Sump Depth: <br />4611 <br />46" <br />4711 <br />Sump Material: <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />1811 <br />1711 <br />17" <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />16" <br />17" <br />16" <br />Condition of sump prior to testing: <br />Dry <br />Dry <br />Dry <br />Portion of Sump Tested' <br />2" above <br />Highest piping <br />penetration <br />Does turbine shut down when <br />sump sensor detects liquid (both <br />x Yes 0 No 0 NA <br />x Yes 0 No 0 NA <br />x Yes 0 No 0 NA <br />0 Yes 0 No 0 NA <br />_product and water)?' <br />Turbine shutdown response time <br />Is system programmed for fail-safe <br />shutdown?* <br />x Yes ONo DNA <br />x Yes 0 No 0 NA <br />x Yes DNo DNA <br />0 Yes 0 No 0 NA <br />Was fail-saoperational?* fe verified to be <br />0 Yes x No 0 NA <br />0 Yes x No 0 NA <br />0 Yes xNo DNA <br />0 Yes 0 No 0 NA <br />Wait time between applying <br />pressure/vacuum/water and starting <br />5 min <br />5 min <br />5 min <br />5 min <br />test: <br />Test Start Time: <br />9:40 <br />10:10 <br />10:50 <br />Initial Reading (RI): <br />.001, <br />.001, <br />.001, <br />.001, <br />Test End Time: <br />10:10 <br />10:40 <br />11:20 <br />Final Reading (RF): <br />.00 <br />.00 <br />.00 <br />Test Duration: <br />30 min <br />30 min <br />30 min <br />30 min <br />Change in Reading (RF -RI): <br />.00 <br />'00 <br />.00 <br />Pass/Fail Threshold or Criteria: <br />.005/30 min <br />.005/30 min <br />.005/30 min <br />.005/30 min <br />Test Result: <br />x Pass 0 Fail <br />x Pass 0 Fail <br />x Pass 0 Fail <br />0 Pass 0 Fail <br />Was sensor removed for testing? <br />x Yes 0 No 0 NA <br />x Yes 0 No 0 NA <br />x Yes 0 No 0 NA <br />0 Yes 0 No 0 NA <br />Was sensor properly replaced and <br />I <br />verified functional after testing? <br />xYes E]No DNA <br />I <br />x Yes El No El NA <br />x Yes El No 11 NA <br />0 Yes 0 No 0 NMA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />' If the entire depth of the sump is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire sump must be tested. (See SWRCB LG -160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.