My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1996-2003
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MARCH
>
2701
>
2300 - Underground Storage Tank Program
>
PR0231176
>
COMPLIANCE INFO_1996-2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/7/2023 3:54:32 PM
Creation date
6/3/2020 9:45:52 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1996-2003
RECORD_ID
PR0231176
PE
2361
FACILITY_ID
FA0003798
FACILITY_NAME
MARCH LANE 76*
STREET_NUMBER
2701
Direction
W
STREET_NAME
MARCH
STREET_TYPE
LN
City
STOCKTON
Zip
95219
APN
11619007
CURRENT_STATUS
01
SITE_LOCATION
2701 W MARCH LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231176_2701 W MARCH_1996-2003.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
324
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A IFIED PROGRAM CONSOLIDATED OM <br /> SITE#255886/5886/31010 <br /> PIPING <br /> UNDERGROUND STORAGE TANKS - TANK PAGE 2 <br /> VI.PIPING CONSTRUCTION(Check all that apply) Page of <br /> PIPINGUNDERGROUND PIPING ABOVEGROUND <br /> SYSTEM TYPE 1.PRESSURE ❑2.SUCTION ❑3.GRAVITY 458 ❑1.PRESSURE ❑2.SUCTION 03.GRAVITY 459 <br /> 1.SINGLE WALL ❑3.LINED TRENCH [:199.OTHER 460 [:11.SINGLE WALL ❑95.XERXES 462 <br /> CONSTRUCTION/ ,DOUBLE WALL ❑95.XERXES ❑2.DOUBLE WALL ❑99.OTHER <br /> MANUFACTURER <br /> MANUFACTURER 461 MANUFACTURER 463 <br /> [:11.BARE STEEL ❑6.FRP COMPATIBLE W 100%METHANOL [:11.BARE STEEL ❑6.FRP COMPATIBLE W/100%METHANOL <br /> MATERIALS AND ❑2.STAINLESS STEEL ❑7.GALVANIZED STEEL ❑2.STAINLESS STEEL ❑7.GALVANIZED STEEL <br /> CORROSION ❑3.PLASTIC COMPATIBLE WITH CONTENTS ❑95.XERXES ❑3.PLASTIC COMPATIBLE WITH CONTENTS ❑8.FLEXIBLE(HDPE) ❑99.OTHER <br /> PROTECTION4.FIBERGLASS ❑8.FLEXIBLE(HDPE) E199.OTHER E:14. FIBERGLASS [:19.CATHODIC PROTECTION <br /> 5.STEEL W/COATING ❑9.CATHODIC PROTECTION 464 ❑5. STEEL W/COATING 095. XERXES 465 <br /> VII.PIPING LEAK DETECTION(Check all that apply)(A description of the monitoring program shall be submitted to the local agency) <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SINGLE WALL PIPING SINGLE WALL PIPING 467 <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> ❑ 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF FOR ❑ 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF FOR LEAK, <br /> LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND VISUAL SYSTEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND VISUAL ALARMS <br /> ALARMS ❑ 2. MONTHLY 0.2 GPH TEST <br /> ❑ 2. MONTHLY 0.2 GPH TEST ❑ 3. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑ 3. ANNUAL INTEGRITY TEST(0.1 GPH) ❑ 4. DAILY VISUAL CHECK <br /> CONVENTIONAL SUCTION SYSTEMS: CONVENTIONAL SUCTION SYSTEMS(Check all that apply): <br /> ❑ 5 DAILY VISUAL MONITORING OF PUMPING SYSTEM+TRIENNIAL PIPING INTEGRITY ❑ 5. DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br /> TEST(0.1 GPH) ❑ 6. TRIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING). <br /> ❑ 7. SELF MONITORING ❑ 7. SELF MONITORING <br /> GRAVITY FLOW: GRAVITY FLOW(Check all that apply): <br /> ❑ 9. BIENNIAL INTEGRITY TEST(0.1 GPH) ❑ 8. DAILY VISUAL MONITORING <br /> ❑ 9. BIENNIAL INTEGRITY TEST(O.1 GPH) <br /> SECONDARILY CONTAINED PIPING <br /> SECONDARILY CONTAINED PIPING PRESSURIZED PIPING(Check all that apply): <br /> PRESSURIZED PIPING(Check all that apply): <br /> 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND(check one) <br /> (Check one) ❑ a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> ❑ a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS ❑ b. AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM DISCONNECTION <br /> b. AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM ❑ c. NO AUTO PUMP SHUT OFF <br /> DISCONNECTION ❑ 11. AUTOMATIC LEAK DETECTOR <br /> ❑ c. NO AUTO PUMP SHUT OFF ❑ 12. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> '*111. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITH FLOW SHUT OFF OR <br /> RESTRICTION SUCTION/GRAVITY SYSTEM: <br /> 12. ANNUAL INTEGRITY TEST(0.1 GPH) t�eIN 1z oS ❑ 13. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS <br /> SUCTION/GRAVITY SYSTEM: EMERGENCY GENERATORS ONLY(Check all that apply) <br /> ❑ 13. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS ❑ 14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF+AUDIBLE AND VISUAL <br /> ALARMS <br /> EMERGENCY GENERATORS ONLY(Check all that apply) ❑ 15. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST) <br /> ❑ 14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF+AUDIBLE AND <br /> VISUAL ALARMS ❑ 16. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑ 15. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITHOUT FLOW SHUT OFF OR ❑ 17, DAILY VISUAL CHECK <br /> RESTRICTION <br /> ❑ 16. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑ IT DAILY VISUAL CHECK <br /> VIII.DISPENSER CONTAINMENT <br /> DISPENSER CONTAINMENT I.FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE ❑ 4.DAILY VISUAL CHECK <br /> DATE INSTALLED 468 2.CONTINUOUS DISPENSER PAN SENSOR+AUDIBLE AND VISUAL ALARMS ❑ 5.TRENCH LINER/MONITORING <br /> ❑ 3.CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR DISPENSER+AUDIBLE AND VISUAL ALARMS ❑ 6.NONE 469 <br /> IX.OWNER/OPERATOR SIGNATURE <br /> I certify th information provided herein is true and accurate to the best of my knowledge. <br /> SIGNA RE OOWNER/OP OR DATE 470 <br /> NAME OF O E OPERATOR(print) 471 TITLE OF OWNE OPERATOR 472 <br /> JANETTE M.THOMPSON FOR CIRCLE K STORES,INC. COMPLIANCE SPECIALIST <br /> Permit Number(For local use only) 473 Permit Approved(For local use only) 474 1 Permit Expiration Date(For local use only)475 <br />
The URL can be used to link to this page
Your browser does not support the video tag.