My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1996-2003
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MARCH
>
2701
>
2300 - Underground Storage Tank Program
>
PR0231176
>
COMPLIANCE INFO_1996-2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/7/2023 3:54:32 PM
Creation date
6/3/2020 9:45:52 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1996-2003
RECORD_ID
PR0231176
PE
2361
FACILITY_ID
FA0003798
FACILITY_NAME
MARCH LANE 76*
STREET_NUMBER
2701
Direction
W
STREET_NAME
MARCH
STREET_TYPE
LN
City
STOCKTON
Zip
95219
APN
11619007
CURRENT_STATUS
01
SITE_LOCATION
2701 W MARCH LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231176_2701 W MARCH_1996-2003.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
324
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Aft Allk <br /> Mr 1W <br /> UNIFIED PROGRAM CONSOLIDATED FORM <br /> TANKS <br /> • UNDERGROUND STORAGE TANKS-TANK PAGE 1 <br /> (taro pages per tank) <br /> Page of <br /> TYPE OF ACTION ❑1. NEW SITE PERMIT ❑4. AMENDED PERMIT ®5. CHANGE OF INFORMATION) ❑6. TEMPORARY SITE CLOSURE <br /> (Check one item only) ❑7. PERMANENTLY CLOSED ON SITE <br /> ❑3. RENEWAL PERMIT <br /> (Specify reason-for Iotal use only) (Specify change-for local use only) [18. TANK REMOVED 430 <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business As) 3 FACILITY ID# _ TF <br /> Tosco Corporation#255886/5886/31010 <br /> LOCATION WITHIHIN/SSITE(Optional) 431 <br /> ()V `5` <br /> ` I.TANK DESCRIPTION (A scaled plat plan with the location ojthe UST system including buildings and landmarks shall be submitted to the local agency.) <br /> TANK ID# I 432 TANK MANUFACTURER 433 COMPARTMENTALIZED TANK ❑ Yes No 434 <br /> f �j Lr n A 1V/f ( �L-�, If I7Yes ,complete one page for each comp m <br /> DATE INSTALLE (YEAR/"`/MOO) 435 TANK CAPACITY ININ+GALLONS 436 NUMBER OF COMPARTMENTS 437 <br /> q5 000 <br /> ADDITIONAL DESCRIPTION(For local use only) 438 <br /> II.TANK CONTENTS <br /> TANK USE 439 PETROLEUM TYPE 440 <br /> I. MOTOR VEHICLE FUEL ❑la. REGULAR UNLEADED ❑ 2. LEADED ❑ 5. JET FUEL <br /> (Ij ked,complete Petroleum Type) ❑lb. PREMIUM UNLEADED3. DIESEL ❑ 6 AVIATION FUEL <br /> ❑ 2. NON-FUEL PETROLEUM ❑lc. MIDGRADE UNLEADED [:] 4. GASOHOL ❑99. OTHER <br /> ❑3. CHEMICAL PRODUCT <br /> ❑ 4. HAZARDOUS WASTE(Includes COMMON NAME(from Hazardous Materials Inventory page) 441 CAS#(from Hazardous Materials Inventory page) 442 <br /> Used Oil) <br /> ❑95. XERXES <br /> III.TANK CONSTRUCTION <br /> TYPE OF TANK ❑11. SINGLE WALL ❑ 3. SINGLE WALL WITH E] 5. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443 <br /> � <br /> (Check one item only) W� DOUBLE WALL EXTERIOR MEMBRANE LINER ❑95. XERXES <br /> ❑ 4. SINGLE WALL IN A VAULT ❑99. OTHER <br /> TANK MATERIAL-primary tank BARE STEEL ❑3. FIBERGLASS/PLASTIC ❑5. CONCRETE ❑95. XERXES 444 <br /> (Check one item only) ❑2, STAINLESS STEEL ❑4. STEEL CLAD W/FIBERGLASS 08. FRP COMPATIBLE W/100%METHANOL ❑99. OTHER <br /> REINFORCED PLASTIC FRP <br /> TANK MATERIAL-secondary tank ❑1 BARE STEEL ❑3. FIBERGLASS/PLASTIC ❑8. FRP COMPATIBLE W/100%METHANOL ❑95. XERXES 445 <br /> (Check one item only) ❑1 STAINLESS STEEL -fa-( STEEL CLAD W/FIBERGLASS ❑9. FRP NON-CORRODIBLE JACKET ❑99. OTHER <br /> REINFORCED PLASTIC(FRP) [:]10. COATED STEEL <br /> ❑5. CONCRETE <br /> TANK INTERIOR LINING ❑ 1. RUBBER LINED ❑3. EPDXY LINING ❑5 GLASS LINING ❑95. XERXES 446 DATE INSTALLED 447 <br /> OR COATING ❑2. ALKYD LINING <br /> ❑4. PHENOLIC LINING �(j UNLINED ❑99. OTHER <br /> Check one item only) For local use only) <br /> OTHER CORROSION ❑1. MANUFACTURED FIBERGLASS REINFORCED PLASTIC ❑95. XERXES 448 DATE INSTALLED 449 <br /> PROTECTION IF APPLICABLE CATHODIC <br /> [:14. IMPRESSED CURRENT [:]99, OTHER <br /> PROTECTION <br /> (Check one item only) 02. SACRIFICIAL ANODE (For local use only) <br /> SPILL AND OVERFILL YEAR INSTALLED 450 TYPE(For local use only) 451 OVERFILL PROTECTION EQUIPMENT.YEAR INSTALLED C 452 <br /> (Check all that apply) <br /> SPILL CONTAINMENT� ❑1. ALARM FILL TUBE SHUT OFF VALVE _/Q 7 7Qv <br /> DROPTUBE i ❑2. BALL FLOAT 4 EXEMPT <br /> 3. STRIKER PLATE <br /> IV. TANK LEAK DETECTION (A description ojthe monitoring program shall be submitted to the local agency.) <br /> IF SINGLE WALL TANK(Check all that apply): 453 IF DOUBLE WALL TANK OR TANK WITH BLADDER(Check one item only): 454 <br /> [-]I, VISUAL(EXPOSED PORTION ONLY) ❑5. MANUAL TANK GAUGING(MTG) 1. VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑2. AUTOMATIC TANK GAUGING(ATG) ❑6. VADOSE ZONECONTINUOUS INTERSTITIAL MONITORING <br /> ❑3. CONTINUOUS ATG F]7. GROUNDWATER 3. MANUAL MONITORING <br /> ❑4. STATISTICAL INVENTORY RECONCILIATION(SIR)+ ❑8. TANKTESTING <br /> BIENNIAL TANK TESTING ❑99. OTHER <br /> V.TANK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455 ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456 TANK FILLED WITH INERT MATERIAL? 457 <br /> gallons _.Yes :No <br /> UPCF(1/99 revised) Formerly SWRCB Form B <br />
The URL can be used to link to this page
Your browser does not support the video tag.