My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MARCH
>
2701
>
2300 - Underground Storage Tank Program
>
PR0231176
>
COMPLIANCE INFO_2012-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/7/2023 4:14:10 PM
Creation date
6/3/2020 9:46:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2018
RECORD_ID
PR0231176
PE
2361
FACILITY_ID
FA0003798
FACILITY_NAME
MARCH LANE 76*
STREET_NUMBER
2701
Direction
W
STREET_NAME
MARCH
STREET_TYPE
LN
City
STOCKTON
Zip
95219
APN
11619007
CURRENT_STATUS
01
SITE_LOCATION
2701 W MARCH LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231176_2701 W MARCH_2012-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
356
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 * RECENED <br /> Monitoring System EquipmentCertifiKati o-fil'`1 2018 <br /> For Use By All Jurisdictions Within The State of California <br /> Authority Cited:Chapter 67, Health and Safety Code;Chapter 16,Division 3, Title 23, Cali/brnif(R*RW90ffY*1'fAL HEALTH <br /> This form must be used to document testing and servicing of monitoring equipment. A separate certification or 16 ENT <br /> 12re2ared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided <br /> to the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST system <br /> within 30 days of test date. <br /> A. General Information <br /> Facility Name:Unocal Bldg.No.: <br /> Site Address: 2701 West March Lane City: Stockton,CA — Zip: 95219 <br /> Facility Contact Person: Manager Contact Phone No.: (209)473-7337 <br /> Make/Model of Monitoring System: VR TLS-350 Date of Testing/Servicing: 12/14/17 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/serviced: <br /> Tank I%01-Rego Tank IQ: 02-Prem <br /> IM In-Tank Gauging Probe. Model: VR 8473MI09 0 In-Tank Gauging Probe. Model: VR 847390109 <br /> N Annular Space or Vault Sensor. Model: VR 794390420 11 Annular Space or Vault Sensor. Model: VR 794390420 <br /> a Piping Sump\Trench Sensor(s). Model: VR 794HO-208 Piping Sump\Trench Sensor(s). Model: VR 794380208 <br /> ❑ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: Vaportess LD2000 Mechanical Line Leak Detector. Model: Vaporless LD2000 <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> Tank Overfill\High-Level Sensor. Model: VR 790091.001 Tank Overfill\High-Level Sensor. Model: VR790091-001 <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and Model in Section E on Page 2). <br /> Tank IQ, 03-Diesel Tank IQ: <br /> N In-Tank Gauging Probe. Model: VR 846400001 [3 In-Tank Gauging Probe. Model: <br /> it Annular Space or Vault Sensor. Model: VR 7943MA20 [3 Annular Space or Vault Sensor. Model: <br /> C1 Piping Sump\Trench Sensor(s). Model: VR794380-208 ❑ Piping Sump\Trench Sensor(s). Model: <br /> 0 Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> 0 Mechanical Line Leak Detector. Model; RJ 116-050.6 ❑ Mechanical Line Leak Detector. Model: <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> Tank Overfill\High-Lovel Sensor. Model: VR 790091.001 13 Tank Overfill\High-Level Sensor. Model: <br /> ❑ Other(specify equipment type and model in Section E on Page 2). [1 Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID; 01-02 Dispenser ID: 03-04 <br /> 0 Dispenser Containment Sensor(s). Model:-- [I Dispenser Containment Sensor(s). Model: <br /> 9 Shear Valve(s). Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID; t05_06 <br /> 10 ub Dispenser ID: 07-08 <br /> ❑ Dispenser Containment Sensor(s). Model: ❑ Dispenser Containment Sensor(s). Model: <br /> 01 Shear Valve(s). Shear Valve(s). <br /> 0 Dispenser Containment Float(s)and Chain(s). C1 Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 09-10 Dispenser ID,• 11-12 <br /> D Dispenser Containment Sensor(s). Model: ❑ Dispenser Containment Sensor(s). Model: <br /> go Shear Valve(s). Co Shear Valve(s). <br /> 0 Dispenser Containment Float(s)and Chain(s). M Dispenser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility <br /> C.Certification- I certify that the equipment Identified in this document was inspected/serviced In accordance with the <br /> manufacturer's guidelines. Attached to this Certification is information(e.g.manufactures'checklists)necessary to verify that this <br /> information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such <br /> reports,I have also attached a copy of the; (check aH that apply): 11 System set-up 0 Alarm history report <br /> Technician Name(print): Kris Bell Signature: <br /> Mfg.Cert.#.: B33709 ICC# 5297793-UT License.No.: 486184 <br /> Testing Company Name: Service Station Systems Phone No.; (408)971-2445 <br /> Testing Company Address: 680 Quinn Ave.,San Jose,CA 95112 Date ofTesting/Servicing: 12114/17 <br />