My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2018
>
EHD Program Facility Records by Street Name
>
M
>
MARCH
>
2701
>
2300 - Underground Storage Tank Program
>
PR0231176
>
COMPLIANCE INFO_2012-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/7/2023 4:14:10 PM
Creation date
6/3/2020 9:46:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2018
RECORD_ID
PR0231176
PE
2361
FACILITY_ID
FA0003798
FACILITY_NAME
MARCH LANE 76*
STREET_NUMBER
2701
Direction
W
STREET_NAME
MARCH
STREET_TYPE
LN
City
STOCKTON
Zip
95219
APN
11619007
CURRENT_STATUS
01
SITE_LOCATION
2701 W MARCH LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231176_2701 W MARCH_2012-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
356
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Ank <br />Aft <br />MW <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />MARCH LANE 76' <br />Facility Address: <br />2701 W March Ln, Stockton <br />Date: <br />December 17, 2014 <br />UST System Observations <br />322 <br />CCR 2636(f)(2) <br />Line leak detector not installed <br />o V ❑ R ❑ COS <br />323 <br />CCR 2636(f)(2) <br />Leak detector failed to detect a 3.0 gph leak at 10 psi <br />❑ V ❑ R ❑ COS <br />324 <br />CCR 2635(b) <br />No spill bucket installed or failed to provide a means to keep it empty <br />❑ V ❑ R ❑ COS <br />325 <br />CCR 2635(b) <br />Spill container failed to contain a minimum capacity of five gallons <br />❑ V ❑ R ❑ COS <br />326 <br />CCR 2635(b)(2) <br />Overfill prevention system not present, was overridden, or failed to meet overfill requirements <br />❑ V ❑ R ❑ COS <br />327 <br />HSC 25283.5 <br />Unburied below grade UST failed to meet exemption status <br />o V ❑ R ❑ COS <br />328 <br />CCR 2717.1(g) <br />Tampered with red tag <br />❑ V ❑ R o COS <br />329 <br />CCR 2717.1(f) <br />Deposited petroleum into a red tagged UST <br />❑ V ❑ R o COS <br />330 <br />HSC 25299(f)(2) <br />Tampered with or disabled leak detection devices or alarms <br />❑ V ❑ R ❑ COS <br />331 <br />CCR 2631.1 <br />UST system not compatible with the substance stored <br />o V ❑ R o COS <br />332 <br />HSC 25298(b) <br />Failed to comply with temporary closure requirements <br />❑ V ❑ R ❑ COS <br />333 <br />HSC 25298(c) <br />Failed to comply with permanent closure requirements <br />❑ V ❑ R ❑ COS <br />Non -Pressurized Piping <br />401 <br />CCR 2636(a)(3) <br />Suction piping not properly sloped or incorrectly located check valve <br />❑ V ❑ R ❑ COS <br />402 <br />CCR 2643(d) <br />Daily monitoring of suction pipe (pre -Jan 1984) not performed <br />❑ V ❑ R ❑ COS <br />403 <br />CCR 2643(d) <br />Triennial 0.1 gph line test for conventional suction piping not performed (pre -January 1984) <br />❑ V o R ❑ COS <br />404 <br />CCR 2643(e) <br />Biennial 0.1 gph test for gravity piping not performed (pre -January 1984) <br />❑ V o R ❑ COS <br />Other Violations <br />2010 <br />See below <br />Unlisted Administration/Documentation violation <br />❑ V ❑ R o COS <br />2030 <br />See below <br />Unlisted Operations/Maintenance violation <br />❑ V ❑ R ❑ COS <br />2060 <br />See below <br />Unlisted Design/Construction violation <br />o V ❑ R ❑ COS <br />SUMMARY OF VIOLATIONS <br />(CLASS 1, CLASS 11, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />103 <br />HSC 25292.2 Current financial responsibility documents not submitted. <br />Financial responsibility documents were not submitted to the EHD during time of inspection. Current financial <br />responsibility documents are required to be submitted annually. The documents were submitted into CERS during the <br />inspection. This is a repeat violation, Class II. <br />126 <br />HSC 25404(e)(4) Failed to report program data electronically. <br />No CERS submittal during time of inspection. This was corrected on site. This is a repeat violation, Class ll. <br />309 <br />CCR 2636(0(1) Monitoring in the UDCs failed to activate an audible and visual alarm or stop the flow at the UDC. <br />The Bravo box float and chain in the 5-6 and 1-2 UDC sump failed to stop the flow of product at the dispenser when <br />tested. All monitoring equipment shall be maintained to activate an audible and visual alarm or stop the flow of product <br />at the dispenser when it detects a leak. The service technician adjusted the chain in 5-6 UDC and changed the Bravo <br />float in 1-2 UDC and verified functionality. This is a repeat violation, Class Il. <br />Recei d by 'tiaq: <br />Inspector <br />FATINAH ZAREEF, REHS <br />Phone., <br />(209) 953-7311 <br />Date: <br />12/17/2014 <br />Page 3 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.