My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2002-2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
6230
>
2300 - Underground Storage Tank Program
>
PR0231225
>
COMPLIANCE INFO_2002-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/9/2020 10:18:53 PM
Creation date
6/3/2020 9:46:24 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002-2009
RECORD_ID
PR0231225
PE
2361
FACILITY_ID
FA0003624
FACILITY_NAME
CANEPAS CAR WASH
STREET_NUMBER
6230
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
08136003
CURRENT_STATUS
01
SITE_LOCATION
6230 PACIFIC AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231225_6230 PACIFIC_2002-2009.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
380
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page ` of <br /> 4. TANK ANNULAR TESTING <br /> Test Method Developed By: Tank Manufacturer ❑Industry Standard ❑Professional Engineer <br /> ❑Other(Specify) <br /> Test Method Used: ❑ Pressure 'Vacuum ❑ Hydrostatic <br /> ❑Other(Spec)' <br /> Test Equipment Used: Equipment Resolution: 3d ii <br /> Tank#I Tank# Tank# Tank# <br /> Is Tank Exempt From Testing?' ❑Yes o ❑Yes I Io ❑Yes ,kNo ❑Yes ❑No <br /> Tank Capacity: t <br /> t L K- !z. <br /> Tank Material: ee <br /> Tank Manufacturer: 1 <br /> Product Stored: <br /> Wait time between applying <br /> pressure/ acuum/-w-hter and <br /> starting test:= Eta!+ <br /> Test Start Time: <br /> Initial Reading(111): 10 H <br /> Test End Time: ; ! 2, <br /> Final Reading(RF): <br /> z <br /> 2 <br /> Test Duration: <br /> Change in Reading(RF-R,): <br /> Pass/Fail Threshold or Criteria: / °� ` Ia <br /> Test Result: ,RPass ❑Fail d°`'Pass ❑Fail sir Pass ❑Fail L7`Pass ❑Fa'1 <br /> Was sensor removed for testing? Z Yes ❑No ❑NA 'Yes ❑No ❑NA - es ❑No ❑r <br /> Was sensor properly replaced and es ❑No ❑NA es ❑No ❑NA Yes ❑No -❑NA O Yes ❑No ❑N <br /> verified functional after testing? <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br /> containment,such as systems that are hydrostatically monitored or under constant vacuum,are exempt from periodic containment <br /> testing. {California Code of Regulations,Title 23, Section 2637(a)(6)) <br />
The URL can be used to link to this page
Your browser does not support the video tag.