My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2002-2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
6230
>
2300 - Underground Storage Tank Program
>
PR0231225
>
COMPLIANCE INFO_2002-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/9/2020 10:18:53 PM
Creation date
6/3/2020 9:46:24 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002-2009
RECORD_ID
PR0231225
PE
2361
FACILITY_ID
FA0003624
FACILITY_NAME
CANEPAS CAR WASH
STREET_NUMBER
6230
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
08136003
CURRENT_STATUS
01
SITE_LOCATION
6230 PACIFIC AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231225_6230 PACIFIC_2002-2009.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
380
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page > of c <br /> 5. SECONDARY PIPE TESTING <br /> 1 Test Method Developed By: b'Piping Manufacturer ❑ Industry Standard ❑Professional Engineer <br /> /❑Other(Spec) <br /> Test Method Used: Q Isressure ❑Vacuum ❑Hydrostatic <br /> ❑Other(Spec) <br /> Test Equipment Used: �7 Equipment Resolution: r�dr� <br /> Piping Run# f Piping Run# Piping Run# Piping Run# <br /> Piping Material: _ <br /> Piping Manufacturer: <br /> Piping Diameter: r' r r t <br /> Length of Piping Run: >rR` l C) l'�� /��}f q��✓ °- (.1' 1 ` �_ ll C? <br /> Product Stored: <br /> Method and location of 4 W/"F'Sy �r� t 1,� ? � „ <br /> piping-run isolation: ar-tjig <br /> , � � �r�t���f� - ..�� -S< /� <br /> aha" � <br /> _ait time between applying / t I ' <br /> pressure/ acuum/water and <br /> tatting test: b 0! 0 I.r o G.,'e <br /> Test Start Time: <br /> Initial Reading(111): <br /> Test End Time: �� j y Z; 35 S-- <br /> Final Reading(RF): <br /> Test Duration: A"'I r-r — 04,,, 1 If 0 fe , <br /> Change in Reading(RF-RI): ) �°.�-- _ ,n 9.e j- <br /> Pass/Fail Threshold or <br /> Criteria: EF1 .I ;¢t ". <br /> Test Result: Pass O Fail Pass ❑Fail Pass ❑Fail IyPass H Fail <br /> Comments—(include information on repairs made prior to testing and recommended follow-up for failed tests) <br />
The URL can be used to link to this page
Your browser does not support the video tag.