My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1997-2007
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
3300
>
2300 - Underground Storage Tank Program
>
PR0231289
>
COMPLIANCE INFO_1997-2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/11/2024 2:08:30 PM
Creation date
6/3/2020 9:46:28 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1997-2007
RECORD_ID
PR0231289
PE
2361
FACILITY_ID
FA0003847
FACILITY_NAME
WEST LANE FUEL
STREET_NUMBER
3300
Direction
N
STREET_NAME
WEST
STREET_TYPE
LN
City
STOCKTON
Zip
95204
APN
11705037
CURRENT_STATUS
01
SITE_LOCATION
3300 N WEST LN
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231289_3300 N WEST_1997-2007.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
387
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AML <br /> D. Results of Ties tingtServicing <br /> Software Version Installed: X <br /> Complete the following checklist: <br /> YYes 0 No*- Is the audible alarm operational? <br /> Yes LI No* Is the visual alarm operational? <br /> Yes Q N& Were all sensors visually inspected,functionally tested,and confirmed operational? <br /> �rYes 13 No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will <br /> not interfere with thew=operation? <br /> Q Yes U No* If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) <br /> Er'N/A operational? <br /> M'Yes U No* For pressurized piping systems,does the turbine automatically shut down if the piping secondary containment <br /> Q N/A monitoring system detects a leak,fails to operate,or is electrically disconnected? If yes: which sensors initiate <br /> positive shut-down? (Check all that apply) 233umpfrrench Sensors; Q Dispenser Containment Sensors. <br /> Did you confirm positive shut-down due to leaks and sensor failure/disconnection? RKes; El No <br /> 0 Yes 13 No* For tank system that utilize the monitoring system as the primary tank overfill warning device (ie. no <br /> 0/N/A mechanical overfill prevention valve is installed),is the overfill warning alarm visible and audible at the tank <br /> fill mt(s)and operating property? If so,at what percent of tank cap!Es does the alarm trigger? <br /> 13 Yes* No Was any monitoring equipment replaced?If yes,identify specific sensors,probes,or other equipment replaced <br /> - and list the manufacturer name and model for all replacement parts in Section F.,below. <br /> 0 Yes* No Was liquid found inside any secondayy containment systems designed as dry systems" (Check all that apply)13 <br /> Product; Q Water. If n,describe causes in Section E,below. <br /> Or"Yes E3 No* Was monitoring system set-AT reviewed to ensure roMset s?Attach set up reports,if applicable <br /> Yes Q No* Is all!j!monitoring �ongpEmanufactureen gEifications? <br /> In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: <br /> Page 2 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.