Laserfiche WebLink
SWRCB,January 2002 Page ' / <br /> b. PIPING SUMP TESTING <br /> Test Method Developed.By: U Sump Manufacturer U Industry Standard afessional Engineer <br /> U Other,(Specify) <br /> Test Method Used: U Pressure U Yacmmm I3ydrostatic. <br /> U Other( cify) <br /> Test&pipmentt Used: l AW d E L 1,..,e.Je L tide w At c A+oV Equipment Resolution:t c-rveja..`!#j"rn Zq4 <br /> EM <br /> Sump# Sump# Z„ Sump# Snmp# <br /> SUMP Diameter4 , <br /> Sump q{S `' L(6 oil IN <br /> Sump Material: lac b <br /> Height from Tank Tap to Tog of <br /> HishEst Piping Penetration: 1 q' ' l�l <br /> Height from Tank Top to Lowest L $ 112,11l (�, <br /> EIectrical Penetration <br /> Condition pf sump prior to testing: G?r °(?it <br /> Portion of Sump Tested' �c�-�P�/L`wZ z�" W Lt►a4 22" <br /> Does turbine shut down when ,Wes U No U NA <br /> sump sensor detects liquid(both KYes U No U NA U Ye UNo U NA LYes. UNo U NA <br /> RM&ct and water)?° <br /> Turbine shutdown response time 3 } 3 Se-c_► <br /> Is system programmed for fail-safe Yea U No U NA <br /> shutdown1v Ya U No U NA U Yes UNo U NA U es UNo UNA <br /> Was fail-safe verified tote Yes UNo U NA XYes U No U NA U Yes U No .0 NA U es U No U NA <br /> Wait time between applying <br /> pressure/vacuu d starting <br /> test: t O d <br /> Test Start Time: <br /> Initial Reading(R j. �r,..�-Grx r"4- <br /> Test End Tjme: 2? b v 12 3 0 <br /> Final Reading(RF):. 4- 6,ted t <br /> Test DivatiEtn: 3O Yn rwk[,� a y <br /> Change in Reading(RI-RI).- lv U 1Jo GGAw <br /> PassfPail Threshold or Criteria: l Cs►zia t'k 3 n wpm <br /> M MEMO <br /> Was sensor removed for testing? , \Yes U No U NA es U No U NAS U UNo U NA Yes UNo U NA <br /> Was sensor replaced and es UNo U NA <br /> Iverifiedfunctional4fter!E!M, h <br /> Yes U No U NA U es UNo U NA Yes U No U NA <br /> � <br /> Comments—('include Infornraaon on nepnzrs made p1m to testing andreconunended olior�unfor• ailed tests <br /> If the entire depth of the sump is not tested,specify how much was tested. If the answer to any of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire sump must be tested. (See SWRCB LO-Ib0) <br />