My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1999-2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
1301
>
2300 - Underground Storage Tank Program
>
PR0231342
>
COMPLIANCE INFO_1999-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/4/2021 3:26:07 PM
Creation date
6/3/2020 9:46:53 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1999-2009
RECORD_ID
PR0231342
PE
2361
FACILITY_ID
FA0000392
FACILITY_NAME
FLAMES LIQUOR
STREET_NUMBER
1301
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95242
APN
03104030
CURRENT_STATUS
01
SITE_LOCATION
1301 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231342_1301 W KETTLEMAN_1999-2009.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
391
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDER DISPE&ER CONTAINMENT ^C) TESTING <br />Test Method By: o Manufacturer • Industry Standard o Professional Engr o Other (see below) <br />Test Method Uses: o Pressure o Vacuum • Hydrostatic o Other (see below) <br />Measuring Equipment Used: INCON TS -STS (Electronic Sump Test System) <br />Descrintion Dist) # 112 Dian # 314 Dian # 516 Dian # 718 <br />UDC manufacturer <br />Bravo <br />Bravo <br />Bravo <br />Bravo <br />UDC material <br />Steel <br />Steel <br />Steel <br />Steel <br />UDC depth (inches) <br />9" <br />9" <br />9" <br />9" <br />Height from UDC bottom to highest <br />Bottom <br />Bottom <br />Bottom <br />Bottom <br />piping penetration <br />0.0761 <br />1.8082 <br />0.9878 <br />0:15 <br />Height from UDC bottom to lowest <br />Bottom <br />Bottom <br />Bottom <br />Bottom <br />electrical penetration <br />0.0009 <br />0.0020 <br />0.0020 <br />0.0020 <br />Condition of UDC prior to testing <br />Dry <br />Dry <br />Dry <br />Dry <br />Portion of UDC tested <br />Entire <br />Entire <br />Entire <br />Entire <br />Type of shut -down present <br />Float <br />Float <br />Float <br />Float <br />Was sensor removed for testing? <br />N/A <br />N/A <br />N/A <br />N/A <br />Was sensor properly replaced after testing? <br />N/A <br />N/A <br />N/A <br />N/A <br />Depth of water level from UDC bottom (in.) <br />Wait time for water level to stabilize (hr:min) <br />Test start time <br />Initial Probe Reading <br />Test end time <br />Final Probe Reading <br />Test duration (hr:min) <br />Change in water level (t 0.0000 inches) <br />Pass/Fail threshold (±0.0020 inches /4' Hr.) <br />TEST RESULT <br />Comments: <br />© 2004 Walton Engineering, Inc. <br />6 <br />6 <br />6 <br />6 <br />0:10 <br />0:05 <br />0:15 <br />0:10 <br />1:31 PM <br />2:21 PM <br />1:31 PM <br />2:21 PM <br />1.4812 <br />0.0759 <br />1.8091 <br />0.9869 <br />1:46 PM <br />2:36 PM <br />1:46 PM <br />2:36 PM <br />1.4824 <br />0.0761 <br />1.8082 <br />0.9878 <br />0:15 <br />0:15 <br />0:15 <br />0:15 <br />0.0012 <br />0.0002 <br />-0.0009 <br />0.0009 <br />0.0020 <br />0.0020 <br />0.0020 <br />0.0020 <br />PASS <br />PASS <br />PASS <br />PASS <br />
The URL can be used to link to this page
Your browser does not support the video tag.